Programming instructions

/M/66-323
DXP Plus Programming instructions
11.1
Toll Restriction Example
“I
In this example, the chief executive can dial all telephone numbers except those numbers with a restriction level
of always deny. The section manager can dial all numbers except those in restriction level 8 (international
numbers over lines assigned
totoll
group 1) and those numbers with a restriction level of always deny. The unit
manager can dial all numbers except those numbers in restriction levels 7 and 8 (international numbers over lines
assigned to toll group 1 and out of state numbers over lines assigned to toll groups 16 and 17) and those numbers
with a restriction level of always deny. All other users can dial all numbers except those in
restrictiow
levels 6
(local calls over lines assigned to toll group
5),
7 (out of state numbers over lines assigned to toll groups 16 and
17),
8 (international numbers over lines assigned to toll group 1) and those numbers with a restriction level of
always deny. All toll restricted stations can dial 1800 numbers on all lines. No toll restricted station can dial
1900 numbers on any line. Note that the feature allows dialing on lines that are not in the toll group. As illustrated
in this example, there is no restriction for international dialing on lines in toll groups
2,5,
16, and 17 and there is
restriction only on lines l-5 in toll group 1.
Toll
Catepory
Chief Executive
Section managers
Unit managers
All other users
Dialing
International 011
Out of state
In state
Local calls
911
1800
1900
Restriction Level
Group
Toll
8
1,
7
16,17
6
5
1
2
Always allow
32
Always allow
32
Always deny
32
Toll
Group
Lines Assigned
1
1,2,3,4,5
2
637
5
12,13
16
14, 15
17
20,25,26,27,28,29,30
32
All Lines
1
l-2 Toll Resfricfiom Programming