Programming instructions

DXP Plus Programming Instructions
IMl66-123
11.2
Poll Restriction Example 2
In this example, assume that you have assigned the following restriction levels and exception numbers to
the
following people in a company: Keep in mind that you assign restriction level to stations by programming the
class of service with a particular restriction level while you assign exception numbers to individual stations
through station programming.
Station
Restriction Level Exception Number
President
8
NONE
Executive
7
NONE
Manager
6
NONE
Joe in sales
1
5
Sally in sales
1
56
Also, assume that you have programmed the following outside numbers, restriction levels and exception numbers
into the toll restriction table:
Number
Restriction Level
Exceotion Number:
1212
7
5
1213@@@@@@@
6
6
978
2
NONE
911
ALWAYS ALLOW NONE
A toll restriction arrangement such as this example permits the following dialing conditions:
the president and the executivecan dial all numbers,
the executive can dial any 1-212 prefixed number, any 1-213 prefixed number (remember,
@
= match any digit),
978 numbers, and 911 (any numbers with restriction level equal to or less than
7),
the manager can dial any 1-213 prefixed numbers, 978 numbers and 911 (any numbers with restriction levels
equal to or less than
6),
Joe (in sales) can dial 911 (via his restriction level) plus dial any 1-212 numbers through his exception number,
Sally (in sales) can dial 911 (via her restriction level) plus dial any 1-212 and 1-213 numbers through her
exception numbers.
(Remember, exception numbers allow Joe and Sally to dial numbers that are denied to them through their
restriction levels.)
Toll Restriction Programming
17-3