Programming instructions

6.8.20
Pulse Dial lnterdiait Time
Description:
You can set the interdigit time between dial pulses when the system pulse-dials a number over a
line. The DXP
Plus
defaults this time to 150 msec. and provides a range of timing values
between 100 msec. and one sec. that you can set in either 50 or 100 msec. increments. Refer to
Section
8.1.9 to enable pulse dialing.
Programming:
1. Press CONTROL T for main menu,
2. From main menu, select system and press ENTER.
3. From the system menu, select timing and press ENTER,
4. From system timing menu type item number for feature and press ENTER,
5. Press SPACE bar to select desired time and press ENTER to select setting.
6.
Press ESCAPE twice,
7. Type y to accept changes, n to reject them, or r to resume editing and press ENTER.
6.8.21
Pulse Dial Make/Pulse Dial Break
(Pulse Dial Ratio)
Description:
Use this procedure to set the make/break ratio for rotary dial signalling to match rotary dial line
requirements. You can set the line make/break ratio for rotary dial (pulse dial) signalling in a
more flexible manner to match many different rotary dial line requirements. You can set the
make time and the break time independently in one msec. increments to any time from one to 99
msec. Refer to
Section
8.1.8
to enable pulse dialing.
Programming: 1.
2.
3.
4.
5.
6.
7.
8.
9.
Press CONTROL T for main menu,
From main menu, select system and press ENTER.
From system menu, select timing and press ENTER,
From system timing menu, type item number for line pulse make and press ENTER.
Type desired time (l-99) and press ENTER,
From timing menu, type item number for line pulse break and press ENTER,
Type desired time (l-99) and press ENTER,
Press ESCAPE twice,
Type y to accept changes, n to reject them, or r to resume editing and press ENTER,
6.8.22
Dialing Complete
Description:
With systems operating with the E-l Digital Carrier Line Board feature, you must use this
timing feature to set the maximum amount of time that a user can wait between digits when he
or she is dialing a number. In the E-l operating enviroment, the central office system will not
wait indefinitely for the caller to completely dial a number. Refer to the central office
specifications for timing requirements.
Programming:
1
e
Press CONTROL T for main menu,
2. From main menu, select system and press ENTER.
3. From the system menu, select timing and press ENTER,
4. From system timing menu type item number for feature and press ENTER,
5. Press SPACE bar to select desired time and press ENTER to select setting.
6.
Press ESCAPE twice,
7. Type y to accept changes, n to reject them, or r to resume editing and press ENTER.
Sys tern Features Programming
6-
23