Programming instructions
/M/66-123
DXP
Pius Programming Instructions
7.1.25
Day Restriction Level/Night Restriction Level
Description:
Use restriction level programming (Section 11.4) to create as many as eight different toll calling
categories based on the freedom to dial various numbers or the restriction from dialing them.
You can assign one of eight different restriction (1-8) levels or assign an “‘allow all” level or a
“‘deny all” level. Level
8
is the least restrictive from a station viewpoint but the most restrictive
from a restriction table viewpoint. (For example, a station with a restriction of 8 is only
restricted from dialing “always deny” numbers and it can dial numbers with restriction levels of
l-8. A station with a restriction level of l-7 cannot dial a number with a toll restriction table
entry of
8.)
The “allow all” entry ensures that the system applies no dialing restriction to a
number (example: 91 I). The “deny
all”
ensures that station user can never a number (example:
l-900).
Use the follwing procedure to ssign a restriction level to a station class of service. Program the
restriction level value that accurately reflects the toll restriction dialing freedom expected by
telephones with this class of service.
Programming:
1
D
Press CONTROL T for main menu.
2. From the main menu, select stations and press ENTER.
3. From the stations menu, select COS programming and press ENTER.
4. Type class of service number (l-32) and press ENTER.
5. From the COS programming menu, type item number for day restriction level
and press ENTER.
6. Type
l-8
for restriction level.
7. Press ENTER for night restriction level, and type l-8 for restriction level.
7. When finished, press ESCAPE twice.
8. Type y to accept changes,
n
to reject them, or r to resume editing and press ENTER.
9. Repeat steps 4-8 for each COS or press ESCAPE to end,
?I.
1.26
System Speed Dial Groups
Description:
The system provides
500
system speed dial numbers. These numbers are divided into 20 groups
with 10 numbers available in each group. Assign none, one, or a range of groups (n
-
nn)
to
each
station class of service. Refer to
Section
6.6 for additional speed dial considerations.
Programming:
1
e
Press CONTROL T for main menu.
2. From main menu, select stations and press ENTER.
3. From stations menu, select COS programming and press ENTER.
4. Type class of service number (l-32) and press ENTER.
5. From COS programming menu, type item number for feature and press ENTER.
6. Type desired value (l-20) and press
ENTER.
7. When finished, press ESCAPE twice.
8. Type y to accept changes,
n
to reject them, or r to resume editing and press ENTER.
9. Repeat steps 4-8 for each COS or press ESCAPE to end.
Operation:
While on hook, dial O-9 or press other speed dial buttons.
7-20 Station
Fea
tares
Programming