- VESTAX CORPORATION OWNER'S MANUAL CD Player CDX-15

10
MIXER SECTION
Remove the fader knob and four
screws securing the fader panel.
Remove the fader unit.
Remove the multi-cable connector
from the fader unit carefully.
Insert the multi-cable connector to the
new fader unit.
Place the fader unit and secure it with
four screws.
12
15
13
14
LEVEL VOLUME (PGM A, PGM B)
Used to adjust the input level of each program.
INPUT LEVEL METER
The LED level meters indicate the input signal level
of each PGM channel.
Please adjust the input level so that 0dB LED lights
on peak.
CROSSFADER
The signal of PGM1 can be monitored when the
cross fader is set to the left side. The signal of PGM2
can be monitored when the cross fader is set to the
right side . When the cross fader is set in the middle,
both programs can be monitored.
The cross fader of the CDX-15 is a user-replaceable
fader for ease of replacement. When the cross fader
is worn out, please replace it with the optional
replacement fader, CF-R.
MONITOR SELECT SWITCH
Used to select the program channel for headphone
monitoring. The signal of the selected PGM channel
can be monitored from the left side of the
headphones. The signal being output can be
monitored from the right side. In the centre position,
MIX is selected, the master signal can be monitored
in stereo.
Remore the multi cable
connector from fader unit.
Remore
four screws
How to replace the fader
CDX-15/E 00.9.12 7:44 PM ページ 10