Product Manual

rev. 12/18/2012 ABLT-H, Manual
Installation
1. Install the lift table on a level, even surface. Anchor the table to the floor with appropriately-
matched anchor bolts. Measure the diameter of the bolt holes in the base of the frame, and
install bolts that are at least 4in. long to anchor the table to the floor.
2. Shim the table to level it if necessary.
NOTE: Grout should be placed under the table base to resist warping and bending
forces applied to the base between shims. Grout around the entire perimeter
of the base frame.
3. Connect main air supply to the control pedestal. If no control pedestal is supplied, see
schematic for air inlet.
NOTE: Use only clean, dry air. Use of a filter/regulator is recommended.
Lift Table Operation
1. To raise the table.
a. Press the lever on the control pedestal to the “UP” position.
b. Release the lever as soon as the table reaches the desired height.
2. To lower the lift.
a. Press the lever on the control pedestal to the “DOWN” position.
Maintenance:
Install the maintenance prop before inspecting or maintaining the table. When performing
maintenance beyond merely applying lubrication to the outer surfaces, use overhead rigging to
secure the tabletop. Maintenance prop installation is explained in FIG. 3 below:
1. Check clamps and hose connections periodically. Verify that all connections are airtight.
Insert maintenance stop
bolt through holes in frame
in front of roller (dashed line
& arrow
)
FIG. 3
: Maintenance
prop installation
FIG. 4: LOCKOUT attachment
p
oint
Lever
arm
Attach
padlock
here
2. Inspect all moving parts to confirm normal motion, cleanliness, and state of wear. If any part
is excessively worn, immediately tag the unit “OUT OF SERVICE” and report the issue to
maintenance personnel.
LOCKOUT/TAGOUT Procedure
: Press the lever arm down to cut off air to the system
(see FIG. 4 above); then attach a padlock to the lever arm through the opening in the
lever arm.
3. Clean the air filter element at least every 3 months.
4. Grease and oil all pivot points and shafts at least every 3 months. Lubricate all pivot points
at least once per day if the table is in high cycle operation. Use 90-weight gear lube (SAE
85W 140 EP) to lubricate pivots and shafts.
5. Grease the upper and lower roller channels.
6. Lubricate pivot points of the lock mechanism.
Page 6 of 7