Product Manual
12
INSTRUCTIONS TO CHANGE PARAMETER SETTINGS
USING DIGITAL KEYPAD
(ON THE DRIVE)
1) Press to switch to the program mode.
a) The following screen will appear:
Indicating the specified parameter group.
b) Use the following keys to change all parameter settings in Step 2.
2) Parameter settings need to be changed.
0-
Prog
Data
Prog
Data
MODE
Press "PROG/DATA" key to select parameter group and to stor
entered data.
"END" displays for approx. 0.5 sec. if input has been accepted.
Press "MODE" to scroll through all status at the drive"
To show the turntable speed on the display, press "mode" three
times after initial power-up. For example, when the turntable is
rotating at 12 rpm, the display will appear as "u 12."
Press "UP" or "DOWN" key to scroll through different parameters.
Press "UP" or "DOWN" key momentarily will change parameter
settins in single-unit increments.
Parameter
0-05
1-100
1-15
2-00
2-01
2-02
Parameter Description
User Definded
Coefficient K
Maximum Output
Frequency:
Auto-Acceleration/
Deceleraton
Source of Frequency
Command
Source of Operation
Command
Stop Method
Setting
SWA-48: d 0.3
SWA-54/60: d 0.2
SWA-48: d 50
SWA-54/60 d 55
d 3
Auto Acceleration /
Decleration
d 3
d I
d I
Coast Stop
Setting Description
SWA-48: 15 RPM
SWA-54/60: 12 RPM
Sets the AC drive's maximum
rotation speed
The AC drive will automatically
adjust the time of acceleration
and decleration to the load.
The turntable speed is deter-
mined by the potentimeter on
the digital keypad.
Drive is controlled by the
external switch: keybad STOP
is enable.
The AC drive stops output
immediately upon command,
and the motor coasts until it
comes to a complete stop.