Emergency Pneumatics. Operating Instructions VETTER Pneumatic Decon Tents Article No. 9987018005 | © Vetter GmbH I 09/14 I Changes and errors excepted.
Vetter Pneumatic Decon Tents Contents 1. Important preliminary remarks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. Description of the product. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.1 Scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.2 Optional accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.3 Correct handling and usage. . .
1. Important preliminary remarks These instructions must be read carefully and complied with at all times to ensure this product is used properly and as intended, to ensure this product provides the greatest possible benefit, and that the entitlements within the scope of the Vetter warranty are preserved. Each use/operation of the pneumatic universal tent requires detailed knowledge and compliance of these instructions.
Vetter Pneumatic Decon Tents 2.2 Optional accessories Article No. Description 1523003700 Valise for PZ 17 Decon 2 L, 265 x 150 cm (104 x 59 inch), yellow, Incl. auto belt latch 1523013300 Valise for PZ 40 3 L, 330 x 160 cm (130 x 63 inch), yellow, incl. auto belt latch 2.3 Correct handling and usage Always use compressed air with the pneumatic decon tents - ever use flammable or aggressive gases. Only Vetter original fittings and parts may be used for the pneumatic decon tents. 2.
4. Operating Instructions Open the packing cover. Lay out the tent at the required location. The ground area must be free of any sharp-edged or pointed objects! The decon tents are designed to be inflated with a blower or with compressed air. 4.1 Operation with blower The inflation connection for blowers is opened when air flows through. Connect the inflation hose of the blower to the inflation connection of the tent.
Vetter Pneumatic Decon Tents 4.3 Use as decontamination tent The water connection for the shower heads and the hand showers is positioned in the blue throughway opening and is a Storz Coupling Size D for water. The filling connection is positioned in the green throughway opening. Therefore this makes any confusion impossible with respect to the connections. PZ 17 Decon 2 L: 1 The tent is subdivided by 1 longitudinal partition into two lines.
Vetter PZ 17 Decon 2 L The Vetter decontamination path (PZ 40 3 L) 4.4 Instructions of the showers The required amount of water can be regulated via the ball valve (1). In order to change the shower curtains the hand showers (2) must firstly be uncoupled and the rubber washers (3) removed. The shower curtain can now be removed by separating the Velcro and pile fabric connections on the vertical support hose and unhooking the eyelets (4) on the insertion basin.
Vetter Pneumatic Decon Tents 4.5 Deflation The deflation of the support frame happens over the inflation connection. To deflate the tent, close the air source (compressed air cylinder, etc.) and disconnect the pressure reducer or the filling hose of the blower. The deflation valve is opened by pressing-in and turning the pin (1) counter clockwise.
4.6 Folding Plan Before repacking, the tent frame and the frame of the shower must be completely empty. 1. The front of the tent is folded lengthwise in four equal sections. L Inflation connector Befüllanschlus Stirnseite Front 2. Then fold the tent five times in the direction of the inflation connector. 3. Now place the tent into the carrying bag.
Vetter Pneumatic Decon Tents 5. Practical Tips 99 The individual separating walls, floor tarps, as well as the tent tarpaulins are removed easily and quickly if and as needed. Hook and loop fasteners are used to attach the tarpaulin to the pneumatic supporting frame. 99 When using tent heaters, avoid blowing heat directly onto parts of the tent. 99 If needed, lights can be suspended from the supporting frame. 99 Additional tents are easily connected using hook and loop overlaps.
6. Press patch firmly onto the pretreated area of the supporting frame and smooth out. 7. Allow unpressurized supporting frame to rest for at least 48 hours. Only the factory is able to repair damage that is more extensive. A trained technician must check the tent and its supporting frame for leaks after the repairs. 8. Technical data Type PZ 17 Decon 2 L Article No. (Set) 1520047000 1520035500 m 4.9 x 3.86 x 2.48 8 x 5.5 x 3.1 ft. 16 x 13 x 8 26 x 18 x 10 m 4.9 x 3.5 x 2.3 8 x 5.1 x 2.
Place your trust in emergency pneumatics! We are the company who can help you, find a solution to your problem! Vetter GmbH A Unit of IDEX Corporation Sales Blatzheimer Str. 10 - 12 D-53909 Zülpich Germany Tel.: +49 (0) 22 52 / 30 08-0 Fax: +49 (0) 22 52 / 30 08-590 Mail: vetter.rescue@idexcorp.com www.vetter.de Article No. 9987018005 | © Vetter GmbH I 09/14 I Changes and errors excepted.