4.3 Deation
The deation of the Pneumatic Hazmat Container happens over
the ination connection. To deate the Pneumatic Hazmat Contai-
ner, close the compressed air cylinder and disconnect the pressure
reducer. Screw the cap o of the lling connection in the counter-
clockwise direction. The deation valve is opened by pressing-in
and turning the pin (1) counter clockwise.
1
Pin before locking Pressing-in + turning Valve open
Fold the Pneumatic Hazmat Container s in the way, that the air can
escape (Folding to the direction of the ination connection). Any
remaining air can be removed with a vacuum adaptor (Item No.:
1700018300) in combination with an construction-site compres-
sor adaptor (Item No.: 1600012000).
2
1
3
Connect the construction-site compressor adaptor (1) to the cou-
pling of the vacuum adaptor (2) and turn it interlocking. Then
tighten the screwable part of t the vacuum adaptor. Now connect
the constructionsite compressor adaptor to the pneumatic stie-
ning frame. Attach the quick-action coupling (3) to the connec-
tion hose of the pressure regulator (pressure approx. 6 bar/87 psi)
and open the hand valve of the pressure regulator slowly. Using
the vacuum adapter the air is sucked out of the Hazmat container
which can then be quickly packed without diculty.
After deation and before packing, the valve
must be unlocked again in order to guarantee
perfect ination when it is next used!
4.4 Care and Maintenance
The Hazmat Container and its ttings are to be cleaned after use.
Cleaning of the Hazmat Container is normally made using warm
water together with a soap solution and dried at room tempera-
ture. DIN 7716 is to be observed when storing for long periods of
time.