5. Inspection
The ination ttings and the Hazmat Container are to be checked
for a perfect and orderly condition each time before and after
use:
9 The stiening frame is free of damage, e.g. tears, cuts, pier-
cings, splits, hard or soft areas caused by chemical or thermal
eects.
9 The PVC foldable container is free of damage, e.g. tears, cuts,
piercings, splits, hard or soft areas caused by chemical or ther-
mal eects.
9 Visual and operational check of the pressure regulator
6. Taking the product out of operation
In case the Pneumatic Hazmat Containers are taken out of ope-
ration then this must be disposed of as special waste. If required,
the manufacturer can supply you with more detailed information
regarding this.
7. Technical data
Type PAB 3000 PAB 5000
Art.-No. (set)
1510000101 1510004001
Size (internal) Ø
cm 225 280
inch 88 110
Size (external) Ø
cm 265 320
inch 104 126
Height
cm 95 95
inch 37 37
Operating pressure
bar 0.5 0.5
psi 7.25 7.25
Test pressure
bar 0.65 0.65
psi 9.4 9.4
Nominal content
l 470 562
cu.ft. 16.6 19.8
Air requirement
l 705 843
cu.ft. 25 30
Capacity
l 3,000 5,000
cu.ft. 106 177
Weight
kg 33 44
lbs 73 97
All rights reserved for technical changes within the scope of product improve-