Technical data
79
7 Winter storage procedure
3 Protective fuel mixture
• Connect the fuel supply pipe to a can lled
with protective diesel fuel, for example ‘Cal-
ibration Fluid’ (ISO 4113) or with a mixture
of 1 part of engine oil
[1]
to 9 parts of clean
fuel
[2]
.
• Use this mixture to run the engine at no
load for approx. 5 minutes.
• Stop the engine.
[2]
Only use CEN EN 590 Diesel fuel.
Preferably water-free fuel.
Collect some fuel from the return pipe,
while engine is running.
VD00136
tip!
Combine running the engine with the
protective fuel mixture with ushing
the raw water circuit with fresh water,
see ‘Winter storage procedure - Raw
water cooling system’.
Caution
Never run the engine under load with
this mixture of fuel and oil.
VD
[1]
Engine oil with protective properties.
E.g.:
- Vetus Marine Diesel Engine Oil 15W40
- Shell Rimula R4 L 15W40