make the powder output uniform.
4. Clean the powder in time
After using for a period of time, the powder pump and spray gun shall be purged
with compressed air once.
5. Correct adjustment
The pressure regulating valve is equipped with a locking device, which can be
locked when pushed and opened when pulled. The knob of each pressure
regulating valve is in the appropriate position (subject to the satisfaction of powder
discharge). If it is found that the pressure adjustment is not large, it shall be
checked in time:
1) Whether the air pressure of the compressor is above 6kg
2) Whether the air circuit leaks
3) Whether the pressure regulating valve is normal. Under normal conditions, the
adjustment of the pressure regulating valve should be relatively easy. Do not use
too much force to adjust the regulator to the bottom (off) counterclockwise or
clockwise (at the maximum). If the pressure adjustment is not large, find out the
cause and remove the fault before using it.
7. Common faults
Fault
phenomenon
Causes and inspection
parts
Explain
The power indicator is not
on
AC power is abnormal or not connected to
high voltage controller.A. whether the
power on the power socket B. whether the
power cord openC. Whether the 1A is the
fuse damaged D. whether the connection
between flat wire and transformer is well
connected
Generally, there will be no
problem with the power cord
and the power transformer itself