10. If a check valve is installed in the plumbing, it must have a
cracking pressure of no more than 2 psi. 11. If applying a sealer or
plumbing tape, be careful to not over tighten, as they may be
sucked into
12. This pump should be wired on its own dedicated circuit. Connect
the positive lead (red) to the positive
terminal of your batte and the negative wire(black) to the
negative terminal of your batte.
13. In an easily accessible location, install a switch to control
electricity to the pump. Turn the pump o when
not used for extended periods or when the tank is empty.
14. The electrical circuit should be protected with an over-current
protection device(fuse) in the positive
lead. This pump requires a 15 amp fuse.
15. The pump circuit should not include any other electrical loads.
16. As the water supply pump is non-essential, reference the wire
Cha under the electrical information. Be
sure to have the correct wire sizing for the length of wire you are
using.
17.After installation, check the voltage at the pump motor. Voltage
should be checked when the pump is operating. Full voltage must
be available at the pump motor at times.
Notes
1. FIexible potable water hose or PEX tubing is recommended
instead of rigid piping at the pump. If you choose to use rigid piping,
provide a sho length of hose between the pipe and the pump to
avoid noise and vibration
2. We does not recommend the use of meta | ttings. When possible,
use the provided plastic ttings. 3.Do not adjust the bypass
personally without the help of technician.
4. Lack of sanitizing and maintenance is one of the main reasons for
the under peormance of the pump. Please do maintenance and
winterize the pump at appropriate times, especially before and after
a period of storage.
5. All 110 VAC pump motors and systems, MUST be ground per local
and state electrical codes.