Instructions / Assembly

Controller operation instructions
Panel Instructions
Operation and using
1
When the controller is switched on, display windows show In index ( P, C, K, S )" and the value of
temperature range for 3 seconds, then it starts running.
2 Temperature and time settings:
Press the “Set” button, the controller runs into the temperature setting state. Re-press the “Set” button, the
controller runs into the time setting state. In setting state, you can use the “◄” , ”▼” and ”▲” buttons to get
the required settings. Press the “set” button again, it returns from the setting state and the settings are saved
automatically.
If the time is set as 0”, the controller will run continuously, the display window of “SV” will display the
set point temperature. If the time set value is not equal “0”, timers start time when the measuring temperature
reaches the set point temperature, the display window of “SV” will display the runtime.
3 When temperature alarm, the buzzer will sound,"
4 When the buzzer sounds, it can be muted by pressing any button.
5“◄” button: In the setting state, it can shift the set value by pressing the button.
6 “▼” button: In the setting state, it can reduce the set value by pressing the button. If press and hold the
button, the set value will reduce continuously.
7 ”▲” button: In the setting status, it can increase the set value by pressing the button. If press and hold
the button, the set value will increase continuously.
8 In setting state, the controller will return to run status if without any key press in one minute.
9If the display window shows “----“, it indicates the fault of temperature.
Internal parameters settings
Press the “Set” button for 3 seconds, controller will display the password prompt “Lc”. Adjust the password
to the required value, then press the “Set” button again, it will run into the internal parameter setting state. if press
the “Set” button for another 3 seconds, it will return to the running state.