User Manual

OPERATORS’ MANUAL · TIG SERIES
4
3. MAIN PARAMETER
MODEL
TIG160S
TIG160SⅡ
TIG200S
TIG200SⅡ
TIG180A
TIG180AⅡ
TIG200A
TIG200AⅡ
TIG200P
TIG200PII
Input voltage (V)
Single-phase AC220V/AC230V 15%
Frequency (Hz)
50/60
Input current (A)
15
21
18
18
21
No-load voltage (V)
42
42
56
56
56
Output current range
10~160A
10~200A
10~180A
10-180A
10-200A
Rated voltage (V)
16.4V
18V
17V
17V
18V
Post-flow time (S)
2.5, 5
2.5, 5
2.5, 5
2.5, 5
5
Arc force range
--
--
--
Automatic
Automatic
Duty cycle
60%
No-load loss (W)
35
35
40
40
40
Arc ignition
HF
Pulse frequency (Hz)
--
--
--
---
LF: 2.5
MF: 200
Efficiency
85%
Power factor
0.93
Insulation class
B
Protection class
IP23
Weight (kg)
8
9
8
8
9
Note: The post-flow time of TIG160SⅡ, TIG200SⅡ, TIG180AⅡ and TIG180PⅡ is 1~10s adjustable.
Schematic block diagram (single-phase input)