Use and Care Manual

- 17 -
IV.Cleaning and maintenance of the condenser
During the working period, the condenser will be covered with dust ,which
will affect the heat dissipation. The cooling effect is poor. It
must be cleaned every two months. It is best to clean it by professional.
Always turn off the power before cleaning, and do not damage the
condenser fins.
Fault Analysis and Solutions
No.
Fault
phenomenon
Cause
Method of exclusion
1
The machine
does not start.
1.The power cord is
not connected.
1.Verify the power cord
and connect it
2.Zero line is not
connected
2.Check the neutral line
and connect it
3.Control power
switch is not turned on
3.Turn on the control
power switch
4.Control power
switch connection
problem
4.Control power switch
connection problem
5.There is a problem
with the PCB
5.Replace the PCB
board
2
Cleaning
function
does not work
1.Loose connection
1.Reconnect the break
2.Motor or capacitor is
bad
2.Repair or replace the
motor or capacitor
3.Contactor is bad
3.Replace contactor