Use and Care Manual

- 18 -
3
The
compressor
docs not run
1.Low voltage
1.Check the supply
voltage
2.Function switch
wiring loose
2.Function switch cable
reconnection
3.Contactor is bad
3.Replace contactor
4.There is a problem
with the PCB
4.Replace the PCB
board
5.Capacitor failure
(220V series)
5.Replace capacitor
6.Compressor is bad
6.Replace compressor
4
Not cooling
1.Refrigerant leak
1.Repair the leak point
and vacuum the
refrigerant
2.Condenser blocked
2.Cleaning the
condenser
3.The fan does not
tum
3.Repair or replace the
fan
5
Can't make ice
cream
1.No material in the
cylinder
1.Add slurry in the
cylinder
2.Unloading puffing
tube blocked
2.Pull out the puffing tube
and clean it up
3.The slurry ratio is
wrong, too thick
3.Reconstitute the
qualified slurry
4.The panel travel
switch is damaged or
disconnected
4.Reconnect the line or
replace the travel switch
5.There is a problem
with the reducer
5.Repair or replace the
gear unit