Use and Care Manual

- 6 -
to allow cold air to enter the machine and allow hot air to escape, to
ensure the condensation cycle of the machine.Clean the dust on the
condenser regularly .
Note: The machine will inevitably be shaken during transportation. It is
best to use it for 4 hours after smoothing.
III.Electrical Connection
1) According to the required power, determine the wire size used in the
connection circuit. All internal lines in the ice cream machines have
been connected before leaving the factory.Simply connect the wires to the
power cord from the lower rear of the machine and connect the ground
wire.
Note: All external wiring, plugs and sockets should meet the requirements
of national standards.
2)The rated voltage deviation of the incoming power supply should not be
too high or too low. If it is
3) too high or too low, the indicator light (red) will flash and alarm (beep),
the machine cooling function will not start.
3Look at the nameplate attached to the rear panel of the machine, to
check if the voltage specified on the machine matches the local power
supply voltage.
4)Be sure to entrust the electrical construction unit to connect the ground
wire.Otherwise, an electric shock may occur in the event of a malfunction
or leakage.(The grounding yellow-green line at the bottom of some
models)
5)Do not damage the power cord or cause it to be damaged or processed.
Gathered into bundles, stretched, barely bent, twisted.
6)When the machine is malfunctioning, turn off the power. If a trip occurs,
contact the store or service personnel.
V.Refrigeration Condition
a.Refrigeration is not allowed when the empty cylinder has a stirring shaft.
b.No cooling when there is water in the tank.