Instructions / Assembly

16
· Service environmental conditions:
IEC/EN 61010-1 600V CATⅢ,Pollution level 2
Altitude < 2000m
Temperature and humidity of working environment:
0~40 (<80% RH, <10 is not considered).
Temperature and humidity of storage environment:
-10~60 (<70% RH, remove the battery).
· Temperature coefficient: 0.1 accuracy / .
· The maximum allowable voltage between the measuring terminal and the
ground: 600V DC or AC RMS.
· Sampling rate: about 3 times / second
· Automatic shutdown: about 10 minutes.
· 6000 Display: the maximum displayed value is 6000
· Range exceeding indication: "OL" is displayed.
· Battery low voltage indication: when the battery voltage is lower than the normal
working voltage, the " " will be displayed on the LCD.
· Input polarity indication: the "-" symbol is automatically displayed.
· Battery: DC 1.5V AAA ×2
· Overall dimension:166mm×78mm×64mm
· Weight: about 268g
Accuracy index
Accuracy: ( reading + digit).
Reference conditions: the ambient temperature is 18 to 28 , and the relative
humidity is not greater than 80%.
AC voltage
Range Resolution Accuracy
60mV 10uV
± (0.8% reading +3 digits)
600mV 100uV
6V 1mV
60V 10mV
600V 100mV