Specifications
Area classification
3LTV, 5 LTV, 8 LTV, 10 LTV, 12 LTV: all can use for pipe tracing
5 LTV, 8 LTV: roof and gutter de-icing
Supply voltage
120V
240V
Maximum maintain or
continuous exposure
temperature (power on/off)
65
Maximum intermittent
exposure
temperature (power on/off)
85
Maximum cumulative exposure 1000 hours
Minimum installation
temperature
-20
Minimum bend radius
at 20: 15mm
at -20
: 35mm
Product
LTV
Thickness (mm)
6
Width (mm)
13
Ground-fault protection
To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or
improperly installed, and to comply with the requirements of Xuhui, agency certifications, and
national electrical codes, 30-mA equipment or 5-mA personnel ground-fault protection must be used
on each LTV heating cable branch circuit. Arcing may not be stopped by conventional circuit
protection.
Description
The LTV pre-assembled self-regulating heating
cables are designed for residential and commercial
metal and plastic pipe freeze protection and roof and
gutter deicing applications.
The LTV pre-assembled cables are available in 1-100
feet lengths for 3LTV and 5LTV, in 1-50 feet length for
8LTV, 10LTV and 12LTV, each comes assembled
with a power cord with or without a plug.
The LTV pre-assembled cables more than 100/50
feet lengths are available comes assembled with a
power cord for terminating in a listed standard
junction box.