3.2.10 Extra Log Window Definition
Extra log windows display selected messages. This definition file entry specifies the following:
The title that will appear at the top of the window.
The log entries that will be displayed.
The menu selection of any spy messages that need to be turned off.
The format of the definition is as follows:
Begin LogExtra, <Window Title>
<Leading text of Log entry to match>
Menu, <Menu definition string for Spy or trace message>
End
An example that is used to display Spy Paging Messages is:
Begin LogExtra, Spy Paging Messages
ETS, Id=CP Spy, SpyId=CP PE ENG_LAYER2_TR 13 13
Menu, CP/Spy/Protocol Stack/Engine/ENG_LAYER2_TR/CP PE ENG_LAYER2_TR 13 13
End
3.2.11 Fault Log Definition
The messages that will be added to the fault log are listed in this section. It has the following format.
Begin Record, Fault Log
ETS, CP Fault
ETS, DSPM Fault
ETS, DSPV Fault
ETS, CP Exe Fault
ETS, CP File Info
End
3.2.12 Default ETS Options
This section defines the default values for the ETS Options dialog. This dialog allows customers to define their
own set of defaults base on the characteristics of their system.
Begin Record, Default ETS Options
InitBaud ,115200
SimCommMode ,0
TxPreambleEnable ,1
UnderFlowEnable ,1
DisableStartupCommands ,0
DnldWinSize ,4
DtrEnable ,0
InitFlashTimeout ,25000
LogWinSize ,1000
MaxMenuEntries ,40
XmtRate ,0
PopupCommStatus ,0
PopupFaultLog ,1
TxPreambleEnable ,12
SpeechDnldAddr ,0x2000000
SpeechUpldAddr ,0x2040000
TraceLogNote ,0