AIR TANK PRECAUTIONS:
IMPORTANT:
a.Theairsourcekitairtankisratedfor200PSImaximum
workingpressure.Donotoverll.Overllingmayresultin
deathorseriousinjury.
b.Tankisnottobeusedasabreathingdevice.
c.AlwayswearANSIapprovedsafetyglasseswhen
operating air tank.
d.Bleedpressurefromtankaftereachuse,andbefore
servicingoraddingattachments.
DRAIN TANK OFTEN TO REMOVE CONDENSATE.
FAILURE TO DRAIN TANK WILL ALLOW TANK TO
RUST INTERNALLY.
a.Toremoveanyaccumulatedcondensationinsidethetank,
bleedpressurefromtankuntilpressureisapproximately
5PSIto20PSI.
b.Drainwaterfromtankbyopeningthedraincockdrainvalve.
c.Ifdraincockisplugged,releaseallairpressurefromtank,
removedrainvalveandclean,thenreinstall.
d.Aftercondensatehasbeendrained,closethedraincock.
IMPORTANT:ObserveairtankDateofManufacture(stamped
ontankleg).Replaceairtank2to5yearsfromdateairtank
wasrstused,orusethedateofmanufactureasreference.
Youradherencetoairtankdrainingguidelineswilldetermine
thereplacementdateofyourairtank.RUSTEDTANKSCAN
FAILCAUSINGEXPLOSIONSORFATALINJURIES.Discard
tank immediately if tank is rusted.
NOTE: Whenusingasafetypressurereliefvalve,pointthe
safetypressurereliefvalveawayfromyourbody.Usethepull
ringonthesafetyreliefvalve;openthereliefvalvetoventany
pressureinsidethetankbeforeattemptingtoservicetank.