User manual

200 PSI FAST-FILL AIR SOURCE KIT
USER MANUAL
COMPRESSOR APPLICATION GUIDE:
ABOUT COMPRESSOR DUTY CYCLE:
CompressorDutyCyclereferstoamountoftimeacompressor
canbeoperatedinagiventimeperiod,at100PSI&ata
standard ambient temperature of 72°F.
DutyCycleiscommonlyexpressedas:
CompressorOnTime/(CompressorOnTime+OffTime)
Asanexample,acompressorthatisratedfor20%dutycycle
meansthatcompressorcanbeoperatedat100PSI@72°F
for8Minutesandrestedfor32Minutes.
8min.on/(8min.on+32min.off)=20%DutyCycle
DUTY CYCLE REFERENCE CHART
DUTYCYCLE@100PSI/72°F MINUTESON/OFF
15% 6Min.On/34Min.Off
17% 7Min.On/30Min.Off
20% 8Min.On/32Min.Off
22% 9Min.On/30Min.Off
25% 10Min.On/30Min.Off
30% 13Min.On/30Min.Off
33% 15Min.On/30Min.Off
100% ContinuousDuty
ABOUT RATED WORKING PRESSURE:
Toensuretroublefreeservicelifeofyourcompressor,always
operate compressor within rated working pressure of the
compressor.Neveruseapressureswitchwithahigher
cut-offpressurethancompressor’sratedworkingpressure.
SPECIFICATIONS:
380CAIRCOMPRESSOR
MotorVoltage: 12Volts
Max.CurrentConsumption: 16Amps
RecommendedFuse: 20Amps
MotorType: Perm.Magnetic
HorsePower: 1/4
Max.WorkingPressure: 200PSI
Max.DutyCycle(@72°F&100PSI): 100%
Max.DutyCycle(@72°F&200PSI): 55%
Max.RestartPressure: 200PSI
Max.AmbientTemperature: 158°F
Min.AmbientTemperature: -40°F
Auto.ResetThermalProtection: Yes