325C - 350C - 400C - 450C COMPRESSOR KIT IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs. - Do not use this product in an area where it can fall or be pulled into water or other liquids. - Do not reach for this product if it has fallen into liquid. - Use this compressor with 12-volt or 24-volt (P/N 32538) DC systems only.
CER 325C - 350C - 400C - 450C COMPRESSOR KIT MOUNTING AND WIRING 1. Disconnect ground cable from vehicle’s battery. 2. Temporarily position the air compressor in the location where it will be mounted. 3. Route ground wire to the negative post of the battery or to an appropriate grounding point and cut ground wire to length as needed. 4. Mount air compressor with the four sets of bolts, nuts, washers, and locking washers provided. (See Fig.
325C - 350C - 400C - 450C COMPRESSOR KIT OPERATING INSTRUCTIONS 1. IMPORTANT: Always operate the compressor at or below the MAXIMUM PRESSURE RATING of the compressor. Please refer to Application & Specifications Sections of this manual for details. 2. Always observe the MAXIMUM DUTY CYCLE of the air compressor. Refer to Compressor Applications and Specifications Sections of this manual for details.
325C - 350C - 400C - 450C COMPRESSOR KIT SPECIFICATIONS • Part No. 32530 / 32533 / 32534 / 32538 / 325C Air Compressor Kit / Silver & Chrome (CE Spec.) Motor Voltage: Max. Current Consumption: Motor Type: Horsepower: Max. Working Pressure: Max. Duty Cycle (@72ºF & 100 PSI): Minutes On/Off (@72ºF & 100 PSI): Max. Restart Pressure: Max. Ambient Temperature: Min. Ambient Temperature: Auto.
325C - 350C - 400C - 450C COMPRESSOR KIT COMPRESSOR APPLICATION GUIDE To ensure that you get the highest level of satisfaction from your compressor’s performance, refer to information below: VIAIR COMPRESSOR REFERENCE CHART COMPRESSOR SERIES DUTY CYCLE (100 PSI @ 72°F) 090 SERIES 9% 092 SERIES 9% 095 SERIES 9% 097 SERIES 10% 098 SERIES 10% 100 SERIES 15% 250 IG SERIES 100% 275 SERIES 25% 280 SERIES 30% 325 SERIES 33% 330 IG SERIES 100% 350 SERIES 100%
325C - 350C - 400C - 450C COMPRESSOR KIT TROUBLESHOOTING GUIDE: PROBLEM: POSSIBLE CAUSE(S) CORRECTIVE ACTION Tank pressure drops when 1. Loose drain cock compressor(s) shut off 2. Check valve leaking 3. Loose connections 1. Tighten drain cock 2. Replace check valve or compressor 3. Check all connections with soap and water solution and tighten Compressor runs continuously and air flow lower than normal 1. Excessive air usage 2. Loose connections 3. Worn piston ring or inlet valve. 4.
COMPRESSOR WIRING DIAGRAM 325C - 350C - 400C - 450C COMPRESSOR KIT Wiring Diagram: (Fuse Not Included) 40A Relay 87 30 85 86 325C, 350C @ 30A 400C, 450C @ 40A - + Fuse Battery To Keyed Power Source Pressure Switch AMERICAN WIRE GAUGE GUIDE 12-VOLT: 15 Edelman Irvine, CA 92618 Length of wire from battery to 949-585-0011 compressor (in feet) Amp Draw www.viaircorp.