480C DUAL PERFORMANCE VALUE PACK (Pewter) PART NO. 48012 (Chrome) PART NO. 48032 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product.
480C DUAL PERFORMANCE VALUE PACK IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs. - Do not use this product in an area where it can fall or be pulled into water or other liquids. - Do not reach for this product if it has fallen into liquid. - Use compressors with 12-volt DC systems only. - This product should never be left unattended during use.
480C DUAL PERFORMANCE VALUE PACK MOUNTING AND WIRING 1. Disconnect ground cable from vehicle’s battery. 2. Temporarily position the air compressor in the location where it will be mounted. 3. Route ground wire to the negative post of the battery or to an appropriate grounding point and cut ground wire to length as needed. 4. Mount each air compressor with the four sets of 13/64” (5 mm) bolts, nuts, washers, and locking washers provided. (See Fig.
80C DUAL PERFORMANCE VALUE PACK OPERATING INSTRUCTIONS 1. IMPORTANT: Always operate the compressors at or below the MAXIMUM PRESSURE RATING of the compressor (200 PSI). 2. Always observe the MAXIMUM DUTY CYCLE of the air compressor. Refer to Compressor Applications and Specifications Sections of this manual for details. Operation exceeding maximum pressure ratings and/or duty cycle will result in damage to the air compressor. 3. Your air compressors are equipped with AUTOMATIC THERMAL OVERLOAD PROTECTORS.
480C DUAL PERFORMANCE VALUE PACK COMPRESSOR APPLICATION GUIDE To ensure that you get the highest level of satisfaction from your compressor’s performance, refer to information below: VIAIR COMPRESSOR REFERENCE CHART COMPRESSOR SERIES DUTY CYCLE (100 PSI @ 72°F) 090 SERIES 9% 092 SERIES 9% 095 SERIES 9% 097 SERIES 10% 098 SERIES 10% 100 SERIES 15% 250 IG SERIES 100% 275 SERIES 25% 280 SERIES 30% 325 SERIES 33% 330 IG SERIES 100% 350 SERIES 100% 380 SERIES
480C DUAL PERFORMANCE VALUE PACK TROUBLESHOOTING GUIDE: PROBLEM: POSSIBLE CAUSE(S) CORRECTIVE ACTION Tank pressure drops when 1. Loose drain cock compressor(s) shut off 2. Check valve leaking 3. Loose connections 1. Tighten drain cock 2. Replace check valve or compressor(s) 3. Check all connections with soap and water solution and tighten Compressor runs continuously and air flow lower than normal 1. Excessive air usage 2. Loose connections 3. Worn piston ring or inlet valve. 4.
15 Edelman Irvine, CA 92618 949-585-0011 www.viaircorp.com 86 85 USER MANUAL 30 86 87 85 12V 40A Relay 30 87 12V 40A Relay Pressure Switch To Keyed Power Source Fuse @ 60A + DUAL “C” MODEL COMPRESSOR WIRING DIAGRAM Battery Rev.
480C DUAL PERFORMANCE VALUE PACK LIMITED WARRANTY: VIAIR Corporation warrants this product, when properly installed and under normal conditions of use, to be free from defects in workmanship and materials for a period of one year from its original date of purchase. To receive warranty service or repair, please contact VIAIR Corporation. Returns should be made within one year of the date of purchase, after a Return Goods Authorization (RGA) number has been assigned by VIAIR Corporation.