User's Manual
Table Of Contents
- T-BERD ⁄ MTS 5800 Handheld Network Test Family Getting Started Manual
- Contents
- About this Manual
- Chapter 1 Introduction
- Chapter 2 Getting Started
- Chapter 3 System Tools
- Chapter 4 Basic Testing
- Chapter 5 Optical Tools
- Chapter 6 Maintenance and Troubleshooting
- Appendix A Specifications
- Physical specifications
- Power specifications
- Supported electrical Ethernet rates
- Clock source (Timing) specifications
- DS1 specifications
- E1 specifications
- E3/DS3/STS-1 specifications
- E4/STM-1e specifications
- SFP specifications
- XFP specifications
- Optical specifications
- Transceiver specifications
- Environmental specifications
- Appendix B Storage and Shipment
- Appendix C Customer Services
- Glossary
Appendix A Specifications
E4/STM-1e specifications
120 T-BERD/MTS 5800 Getting Started Manual
Physical
measurements
(E4 circuits)
Table 30 lists frequency and level measurement specifica-
tions when running E4 applications.
Receiver
(STM-1e
circuits)
Table 31 lists specifications for the receiver when running
STM-1e applications.
Table 30 E4 frequency and level measurement specifications
Parameter Specification
Tx and Rx
Frequency
– Range: 139.264 MHz ±100 ppm
– Accuracy: ±1.5 ppm, ±1 ppm per year aging
– Resolution: 1 Hz, or 1 ppm
Level Vpp – Range: 1.4 V to 0.01 V
– Resolution: 0.01 V
– Accuracy: ±0.02 V ±10%
Table 31 STM-1e receiver specifications
Parameter Specification
Connector One BNC
Bit rate 155.52 Mbps
Impedance Nominal 75 Ω at 78 MHz unbalanced
Range Term: 0 to 12.7 dB due to cable loss at 78 MHz, from a
nominal signal
PMP: -20 dB due to resistive loss in addition to 0 to 12.7 dB
due to cable loss at 70 MHz, from a nominal signal