Chapter 2 Getting Started
Navigating the user interface
22 T-BERD/MTS 5800 Getting Started Manual
Various other messages may appear briefly, for example, to
alert you that loop ups are successful. You can display a log
of messages by clicking anywhere on the message bar.
Quick Config
settings
After you select a test application (using the Test menu), a
Quick Config tab appears under the Message Bar, with key
settings required to configure your test. For example, if you
selected the SONET -> OC-192 -> OC-192c Bulk BERT - >
Terminate application, quick configuration settings appear
that allow you to automatically detect and insert a BERT
pattern. See Figure 9.
Signal
Structure
If you are running a SONET, PDH, or SDH application, a
Signal Structure tab appears to the right of the Quick Config
tab. When selected, the Tx side shows the structure of the
signal sent out by the test set, and the Rx side shows the
structure of the signal that the test set is configured to receive.
Figure 10 illustrates the signal structure when you transmit a
Bulk BERT payload in an STS-48c signal
LED Panel
The LEDs in the panel to the left of the Results Windows help
you determine whether a signal is present, pattern synchroni-
zation has been achieved, and other key events when
performing tests.