XX134-60-01 Quick Guide for SurveyorVFT Camera Domes Warning: To reduce a risk of fire or electric shock, do not expose the indoor unit to rain or moisture. Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed to be used in life-critical situations and must not be used for this purpose.
Important Safeguards GRAPHIC SYMBOL EXPLANATION 12. Power Cord Protection - Power supply cords should not be routed in trafficked areas or in tight spaces where they will be pinched or used to bear weight. Allow some slack in the cord where it enters the unit. 13. Outdoor Cable Grounding - Use only grounded outdoor cables to protect against voltage surges and static charges.
Introduction This Quick Guide provides an overview for installing the standard SurveyorVFT PTZ Camera Dome, the SVFT-M Impact-Resistant model, the SVFT-PRS Pressurized version and the SurveyorVFT Fixed models (coaxial, UTP, fiber and ViconNet versions). An abbreviated programming guide is also provided for the camera domes, excluding the fixed versions. For ViconNet (IP) setup and programming, refer to the VN Setup section in the complete manual for the specific SurveyorVFT Camera Dome type.
Q U I C K Quick Installation – Standard PTZ In-Ceiling Model I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N 2 • Introduction XX134-60-01 Rev 108 SurveyorVFT Camera Dome Quick Guide
Q U I C K Quick Installation – Standard PTZ Indoor Pendant I N S T A L L A T I O N XX134-60-01 Rev 108 SurveyorVFT Camera Dome Quick Guide Q U I C K I N S T A L L A T I O N Introduction • 3
Quick Installation – Standard PTZ Outdoor Pendant Q U I C K Q U I C K I N S T A L L A T I O N I N S T A L L A T I O N 4 • Introduction XX134-60-01 Rev 108 SurveyorVFT Camera Dome Quick Guide
Q Quick Installation – SVFT-M Impact-Resistant U I C K Q U I C K I N S T A L L A T I O N I N S T A L L A T I O N XX134-60-01 Rev 108 SurveyorVFT Camera Dome Quick Guide Introduction • 5
Quick Installation – SVFT-PRS Pressurized Q U I C K Q U I C K I N S T A L L A T I O N I N S T A L L A T I O N 6 • Introduction XX134-60-01 Rev 108 SurveyorVFT Camera Dome Quick Guide
Quick Installation – Fixed Q U I C K In Ceiling, No Access to Ceiling Q U I C K I N S T A L L A T I O N XX134-60-01 Rev 108 SurveyorVFT Camera Dome Quick Guide I N S T A L L A T I O N Introduction • 7
Quick Installation – Fixed In-Ceiling – Access to Ceiling Q U I C K Q U I C K I N S T A L L A T I O N I N S T A L L A T I O N 8 • Introduction XX134-60-01 Rev 108 SurveyorVFT Camera Dome Quick Guide
Quick Installation – Fixed Q U I C K Indoor Pendant Q U I C K I N S T A L L A T I O N XX134-60-01 Rev 108 SurveyorVFT Camera Dome Quick Guide I N S T A L L A T I O N Introduction • 9
Q U I C K Quick Installation – Fixed Outdoor Pendant I N S T A L L A T I O N I N S T A L L A T I O N 10 • Introduction Q U I C K XX134-60-01 Rev 108 SurveyorVFT Camera Dome Quick Guide
Wiring and Setup Pin Connections – Standard SurveyorVFT and SVFT-M CONNECTOR/PIN NUMBER CONNECTOR TYPE CONNECTOR/PIN LABEL SIGNAL NAME BNC (female) VIDEO (J1) VIDEO J2 Video output J1 AMP Header (Fiber Optic board)* TERMINAL BLOCK J2 Video/RS-422 data POWER (TB1) TB1-1 Hot H N TB1-2 Neutral TERMINAL BLOCK ALARM (TB2) TB2-1 Alarm input 1 ALARM 1 TB2-2 Ground GND TB2-3 Alarm input 2 ALARM 2 TB2-4 Ground GND TB2-5 Alarm input 3 ALARM 3 TB2-6 Ground GND TB2-7 Alarm input 4 ALARM 4 GND TB2-8 Ground TERM
Wiring Connections – UTP Version 12 • Wiring and Setup XX134-60-01 Rev 108 SurveyorVFT Camera Dome Quick Guide
CONNECTOR/PIN NUMBER CONNECTOR TYPE CONNECTOR/PIN LABEL TERMINAL BLOCK POWER (TB3) H N ALARM (P1) ALARM OUT GND ALARM IN LAN (J7) TX + TX RX + POE POWER POE POWER RX POE POWER POE POWER TB3-1 TB3-2 TERMINAL BLOCK P1-1 P1-2 P1-3 RJ-45 J7-1 J7-2 J7-3 J7-4 J7-5 J7-6 J7-7 J7-8 1/8-IN.
Pin Connections – SurveyorVFT Fixed Both power and video connections are made to the integral printed circuit board (PC board) on the camera mechanism. The PC board provides a board-mounted BNC connector for coaxial, a screw terminal for twisted pair video, an ST connector for fiber-optic or an RJ-45 connector on the ViconNet board for video connection and a removable two-position screw terminal connector for camera power.
Programming the SurveyorVFT Programming is done by selecting options from the on-screen menu system using the AP (autopan), AI (autoiris), joystick and AUX1/AUX2 functions. The cursor wraps around when moving up and down. The following is a description of these controls: AP: select and store parameters; go forward through the menu system. AI: leave or exit a menu without retaining the new setting. Joystick Left/Right: select specific program parameters.
Preset 93 (Set Response Line Polarity) (Duplex Only) — The SurveyorVFT checks for polarity of the command in lines through the auto baud detect feature. The baud detect cycles through 4800+/4800/9600+/9600-/19200+/19200-, indicating not only the baud rate it is searching for but also the polarity that the receive lines are set to. When preset 93 is selected, the dome will periodically cycle the polarity of the COMM IN+ and COMM IN- lines.
• To clear the autopan limits — Store preset 98. Press AUX 2 and AUX 3 without panning to set the autopan limits to the same position. By recording both limits on the same point they will both be deleted. The dome will now rotate continuously when placed in autopan mode until new limits are programmed. Recalling presets 98 has no effect. Preset 99 (Set Manual Pan Limits) — Storing preset 99 will bring up a series of prompts to set the left and right manual pan limits with the AUX 2 and AUX 3 keys.
Vicon Standard Equipment Warranty Vicon Industries Inc. (the “Company”) warrants your equipment to be free from defects in material and workmanship under Normal Use from the date of original retail purchase for a period of three years, with the following exceptions: 1. 2. 3. 4. 5. VCRs, all models: Labor and video heads warranted for 120 days from date of original retail purchase. All other parts warranted for one year from date of original retail purchase.
Vicon Industries Inc.