Alternate Mounting Configuration
b) Refer to Wiring section and Table 2 to make all
connections to terminal block TB1 (power), TB2
(alarms), TB3 (relays/control signals) and TB4
UTP video). On TB3, the COMMAND IN +
(CI+) and COMMAND IN - (CI-) connections
must be used for Simplex operation. For Half
Duplex operation, the additional signals
RESPONSE OUT + (RO+) and RESPONSE
OUT - (RO-) must also be used. Insert each
wire into its proper terminal block location and
tighten the screw.
c) Terminate the video (coaxial) cable with a BNC
type male connector, if not previously done.
Refer to Wiring section for video connections
for fiber-optic or ViconNet optional video
transmissions.
d) Terminate the 8-conductor alarm cable or communication/relay cable.
9. Slide excess cable back up into the mount/pipe so that cable length is flush with the bottom of the
housing, approximately 8 - 9 inches (203 - 229 mm).
Note: There should be minimal wire slack at all connection points.
10. Install the terminal blocks TB1, TB2, TB3 and TB4 into the Customer Interface Board at the proper block
frames. Install the video BNC cable connector to the Customer Interface Board’s mating BNC connector
at location J1 (for coax installations) or connect twisted-pair video wires to screw terminal TB4 (for UTP
installations). Refer to the Wiring section for video connections for fiber-optic and ViconNet versions.
Figure 16
Unlatching the Customer Interface
Board
11. Swing the customer interface board back into place. If
interface board was completely removed, be sure to
reinstall it correctly, with the white connector near the wall
of the enclosure. Refer to Figure 16. After wiring is
complete, dress cables up over board
12. Configure the SurveyorVFT communication/protocol and
address DIP switches on the main board at this time. Refer
to the Setting the DIP Switch section of this manual.
XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 4BInstallation 23