Product specifications
XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 12BReference • 67
Network Cable
Caution: Careful selection of proper cable is essential to obtain the best performance. Vicon assumes no responsibility for poor
performance when cables other than the recommended types, or equivalent, are used.
aterials
able Types
M
Use pure copper stranded conductors to obtain a low DC resistance. The preferred insulation and cable jacket is Polyvinyl
chloride (PVC). It has better electrical characteristics than Polyethylene and resists flames, sunlight and most solvents, but
is more vulnerable to moisture.
C
The most commonly used cable types are CAT5, CAT5e and CAT6. These category cables are best suited for Ethernet
network applications.
Choose a Belden cable type by referring to the characteristics listed below. The Table below should be used as a
guideline when cables other than Belden are used. Materials and construction must follow the guidelines above.
CABLE TYPE WIRE SIZE
(AWG)
INSULATION
MATERIAL
JACKET
MATERIAL
CATEGORY BANDWIDTH
(MHz)
MAXIMUM
DISTANCE
(ft/m)
NUMBER OF
TWISTED
PAIRS
Belden 1624P
24
Fluorinated
Ethylene
Propylene
Low Smoke
PVC
5 100 246/75
4
Belden 1583
A
24 Polyolefin PVC 5e 100 328/100 4
Belden 1585A
24
Fluorinated
Ethylene
Propylene
PVC 5e 100 328/100
4
Belden 7883
A
24 Polyolefin PVC 6 250 328/100
4
Belden Inc. http://www.belden.com/ (800) 235-3361
Table
Recommended Network Cable Types