4. If you suspect the firmware upgrade for the camera has failed, always wait at least 5-10 minutes
before restarting the upgrade process.
5. Vicon reserves the right to charge for any camera repair which can be attributed to faulty
upgrading by the user. Always read the upgrade instructions and firmware release notes before
updating the firmware.
System Reset (Factory Default Reset)
There are two ways to reset the camera back to factory default.
Using the web browser:
1. Go to SETUP > System > Maintenance.
2. Click Factory Default Button and wait 1 minute for camera to reboot.
Using the Reset Button on the camera:
1. After the camera is powered up, i.e., LED is steady green, press and hold the Reset button until
the Status Indicator color changes to RED and starts blinking rapidly (this may take up to
15 seconds).
2. Release the Reset button.
3. When the Status Indicator changes to Green (which may take up to 1 minute), the process is
complete and the camera has been reset.
NOTE: The unit will now have the default IP address from a DHCP server.