Quick Reference Guide

1
2
3 4 5 6 7
Building
Function
Applications /
Features
Function
Outputs /
Inputs
Motion
Sensor
BACnet Wireless
Commercial
Rooftop/Heat pump
Single fan speed
Frost protection
By-pass damper
Economizer
Roof Top Unit
Controller
On-Off,
2H/2C
SEZ7656R1045B SEZ7656R1045W
Heat pump,
3H/2C
SEZ7656H1045B SEZ7656H1045W
On-Off, 2C,
Analog heat
SEZ7656F1045B SEZ7656F1045W
On-Off, 2H/2C,
CO
2
Econo.
SEZ7656E1045B SEZ7656E1045W
Pressure dependent
VAV zone control
Binary inputs
CO
2
input
Zone Controller
Floating
damper
Heat
Reheat
SEZ7260C5545B SEZ7260C5545W
SEZ7260C5045B SEZ7260C5045W
Analog damper
Heat
Reheat
SEZ7260F5545B SEZ7260F5545W
SEZ7260F5045B SEZ7260F5045W
SEZ7656 & SEZ7260 Controllers
Low Voltage (24VAC) Zoning System Applications
1 2 3 4 1 2 3
Building
Function
Applications /
Features
Outputs /
Inputs
Relay Pack
Humidity
Control
Motion
Sensor
Network Ready
Controller
Commercial
2 or 4 pipe
Up to 3 speed
fan control
2 Binary inputs
(SER7300)
Auto changeover
4 pipe or 2 pipe
+ reheat
*
On-Off, 1H/1C
SC3500E5045
SER7350A5545(X)
On-Off ,1H/1C,
4 remote inputs,
SC3504E5045
SER7350A5045(X)
On-Off , 1H/1C,
4 remote inputs,
Occ output
SC3514E5045
Sames as above
but 2 pipe only or
2 pipe + reheat
*
On-Off , 1H/1C,
Pulsed reheat
SC3400E5045 SER7300A5545(X)
On-Off, 1H/1C,
Pulsed reheat,
4 remote inputs
SC3404E5045
SER7300A5045(X)
Up to 3 speed
fan control
SC3300E5045
Hospitality / Lodging
2 or 4 pipe
Up to 3 speed
fan control
2 Binary inputs
(SER7300)
Auto changeover
4 pipe or 2 pipe
+ reheat
*
On-Off, 1H/1C
SC3500E5045
SER7355A5545(X)
On-Off, 1H/1C,
4 remote inputs,
SC3504E5045
SER7355A5045(X)
On-Off, 1H/1C,
4 remote inputs,
Occ output
SC3514E5045
Sames as above
but 2 pipe only or
2 pipe + reheat
*
On-Off, 1H/1C,
Pulsed reheat
SC3400E5045 SER7305A5545(X)
On-Off, 1H/1C,
Pulsed reheat,
4 remote inputs
SC3404E5045
SER7305A5045(X)
Up to 3 speed
fan control
SC3300E5045
SER7300 Controllers & SC3000 Relay Pack
Line Voltage Fan Coil Unit Applications
*
SC3000 model with inputs required for 2 pipe with changeover sensor
*
Does not apply to all models, refer to specic model technical manual for details
1 2 3 4 5 6
Building
Function
Applications / Features
Humidity
Control
Outputs /
Inputs
Motion
Sensor
Network Ready
Controller
Zone
2 or 4 pipe
Hot/chill water valves
Automatic changeover
Auxiliary contact output
Binary Inputs
Floating
or On-Off,
1H/1C,
Reheat
SE7200C5545(X)
SE7200C5045(X)
Analog,
1H /1C,
Reheat
SE7200F5545(X)
SE7200F5045(X)
Commercial
2 or 4 pipe
Up to 3 speed fan control
Hot/chill water valves
Automatic changeover
Auxiliary contact output
Binary inputs
Floating
or On-Off,
1H/1C,
Reheat
SE7350C5545(X)
SE7350C5045(X)
Analog,
1H/1C,
Reheat
SE7350F5545(X)
SE7350F5045(X)
Floating
or On-Off,
1H/1C,
Reheat
SE7300C5545(X)
SE7300C5045(X)
Analog,
1H/1C,
Reheat
SE7300F5545(X)
SE7300F5045(X)
ECM fan control
2 pipe
Hot/chill water valve
Automatic changeover
Auxiliary contact output
Binary inputs
Analog,
1H/1C,
Reheat
SE7300F5545(X)-ECM
SE7300F5045(X)-ECM
Hospitality / Lodging
2 or 4 pipe
Up to 3 speed fan control
Hot/chill water valves
Automatic changeover
Auxiliary contact output
Binary inputs
Floating
or On-Off,
1H/1C,
Reheat
SE7355C5545(X)
SE7355C5045(X)
Analog,
1H/1C,
Reheat
SE7355F5545(X)
SE7355F5045(X)
Floating
or On-Off,
1H/1C,
Reheat
SE7305C5545(X)
SE7305C5045(X)
Analog,
1H/1C,
Reheat
SE7305F5545(X)
SE7305F5045(X)
ECM fan control
2 pipe
Hot/chill water valve
Automatic changeover
Auxiliary contact output
Binary inputs
Analog,
1H/1C,
Reheat
SE7305F5545(X)-ECM
SE7305F5045(X)-ECM
SE7200 & SE7300 Controllers
Low Voltage (24VAC) Zone and Fan Coil Unit Applications
SE7600 Controllers
Low Voltage (24VAC) Rooftop and Heat-Pump Applications
1
2
3 4 5 6
Building
Function
Applications / Features Scheduling
Outputs /
Inputs
Motion
Sensor
Network Ready
Controller
Commercial
Roof top
*
Heat pump
*
Single fan speed
Frost protection
Auxiliary contact output
*
Digital inputs
*
Discharge air sensor
Outdoor air sensor
*
Remote sensor
*
On-Off,
1H/1C
SE7600A5545(X)
SE7600A5045(X)
On-Off,
2H/2C
SE7600B5545(X)
SE7600B5045(X)
Heat pump,
1, 2 compressors
Rev. valve
Aux. heat
SE7600H5545(X)
SE7600H5045(X)
On-Off, 2H/2C,
Humidity
SE7607B5545(X)
SE7607B5045(X)
On-Off,
2H/2C,
Economizer
SE7605B5545(X)
SE7605B5045(X)
WaterSource HP
1, 2 compressors
Rev. valve
Humidity
SE7600W5545(X)
SE7600W5045(X)
On-Off, 2H/2C,
Analog heat,
CO
2
control
Economizer
SE7606E5545(X)
SE7606E5045(X)
On-Off, 2C,
Analog heat
SE7600F5545(X)
SE7600F5045(X)
On-Off,
1H/1C
SE7652A5545(X)
SE7652A5045(X)
On-Off,
2H/2C
SE7652B5545(X)
SE7652B5045(X)
Heat pump,
1, 2 compressors
Rev. valve
Aux. heat
SE7652H5545(X)
SE7652H5045(X)
On-Off, 2H/2C,
Humidity
SE7657B5545(X)
SE7657B5045(X)
On-Off,
2H/2C,
Economizer
SE7656B5545(X)
SE7656B5045(X)
WaterSource HP
1, 2 compressors
Rev. valve
Humidity
SE7652W5545(X)
SE7652W5045(X)
On-Off, 2H/2C,
Analog heat,
CO
2
control
SE7656E5545(X)
SE7656E5045(X)
On-Off, 2C,
Analog Heat
SE7652F5545(X)
SE7652F5045(X)
COMMUNICATION OPTIONS
Replace (X) with one of the following letters for communication protocols:
BACnet
®
4
B
Echelon
®
4
E
Wireless
4
W
ZigBee
®
Pro
4
P Network Ready
4
None
Models without Echelon option
www.schneider-electric.com
SE7000 Quick Reference Guide

Summary of content (1 pages)