Instruction Manual

FlatPAC-EN™ and FlatPAC-EN MI
EN Compliant Autoranging Switcher
Overview
The FlatPAC-EN/EN MI is an ultra low profile switching power supply that provides up to 500 Watts from up to 4
isolated outputs. It operates on either 115 or 230 Vac nominal (47-63 Hz), or 250-380 Vdc. It can be populated
with either VI-200/VI-J00 or Maxi/Mini/Micro Vicor converters. The use of these converters gives the FlatPAC-
EN/EN MI the inherent power flexibility typical of all Vicor products. With dimensions of 1.4" H (35,6mm) x 5.0"
W (127mm) x 9.2" L (233,7mm), the FlatPAC-EN/EN MI provides a power density greater than 7W/in
3
. It is facto-
ry configured to meet user output requirements. Note: The FlatPAC-EN/EN MI does not have an internal fan.
The MI version is a rugged chassis designed specifically for COTS and harsh environment applications
Using the PowerBench configurator tool available on vicorpower.com, anybody can now configure a FlatPAC-EN
(and other Westcor power supplies) online.
Standard Features
Power Factor Correction (passive): Power Factor (Typical) 0.70 (>75% Load)
Input Voltage: 90-132/180-264 Vac
1
, 47-63 Hz, or 250-380 Vdc
Maximum Power Output: 500W (105/190Vac min.)
425W for EN61000-3-2 compliance
Up to 4 isolated user specifiable outputs
Conducted EMI: FCC Class A EN 55022 Class A
FCC Class B EN 55022 Class B
Mil-STD 461 may require external filter
• Harmonic Attenuation to EN61000-3-2/A14
2
Compliant to EN61000-4-4 (Electrical Fast Transient/Burst) and EN61000-4-5 (Surge Immunity)
MI version meets Mil-STD 810 for Shock and Vibration with extended temp range
• MI version also available with -40C temp rating
Efficiency (typical) > 70%
Autosense
3
RS-232 microcontroller interface
Output overcurrent protection on all outputs
Size: 1.4" H (35,6mm) x 5.0" W (127,0mm) x 9.2" L (233,7mm)
Safety Agency Approvals: cURus, cTUVus, CE Mark
1
Derates to 260W@90Vac, 400W @ 180 Vac.
2
For output power 425W, not to exceed an input current of 3.33 A rms at 230 Vac, 50 Hz.
3 This feature is implemented in all converter slots (except with Micro modules). Autosense allows automatic local sensing
when remote sense connections are not made. The FlatPAC-EN/EN MI will operate in remote sense mode when remote
sense connections are made. Refer to page 16 for more information on Autosense.
Optional Features
Current Share Board for unit to unit power sharing - See page 26 and page 27
Connector kits (# 19-130044)
• Conformal coating available on select MI models - contact factory
-40oC Operation, Mil-STD 810 Shock and Vibration (MI rugged chassis only)
Part Numbering
FlatPAC-EN/EN MI FLx
1
-x
2
x
3
-xxxx (-x
4
)(-x
5
)x
1
Number of outputs
e.g. FL4-13-6544 x
2
Number of VI-200/VI-J00 modules
x
3
Number of Maxi/Mini/Micro modules
xxxx Sequential number assigned by Westcor
(-x
4
) Optional Factory assigned: G - RoHS
(-x
5
) Optional versions
Note: x
5
= MI for rugged chassis, = MC for rugged chassis with conformal coating
03-000050 rev A Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474 Pg. 3
FlatPAC-EN/EN MI Design Guide