User Manual

03-000050 rev A Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474 Pg. 11
FlatPAC-EN/EN MI Design Guide
Output Connectors for FlatPAC-EN/EN MI
2
3
4
5
6
7
8
11
12
13
14
15
16
17
1
10
9
18
MATING CONNECTOR:
18 PIN HOUSING: MOLEX (39-01-2180)
TERMINAL FEM CRIMP 18-24 AWG: MOLEX (39-00-0039)
USE CRIMP TOOL: MOLEX (11-01-0197)
10-32 OUTPUT STUDS
- SENSE
3
SxJ2 REMOTE SENSE/TRIM
PIN CONNECTOR
1
2
TRIM
+ SENSE
MATING CONNECTOR:
HOUSING: MOLEX (50-57-9403)
TERMINAL FEM CRIMP 24-30 AWG: MOLEX (16-02-0103)
USE CRIMP TOOL: MOLEX (11-01-0208)
B. 18 PIN MOLEX CONNECTORS - when configured only with half bricks
A. STUD OUTPUT CONNECTOR - when configured with full brick and/or half brick
-V OUT
+V OUT
C. 18 PIN MOLEX CONNECTORS - when configured with half and/or quarter bricks
Refer to page 6 to review configuration layout of FlatPAC-EN
MATING CONNECTOR:
18 PIN HOUSING: MOLEX (39-01-2180)
TERMINAL FEM CRIMP 18-24 AWG: MOLEX (39-00-0039)
USE CRIMP TOOL: MOLEX (11-01-0197)
2
3
4
5
6
7
8
11
12
13
14
15
16
17
1
10
9
18
10 N/C
11 N/C
12 N/C
13 + SENSE M1
14 N/C
15 - SENSE M1
16 +V OUT M1
17 -V OUT M1
18 -V OUT M1
PIN DESCRIPTION
1 N/C
2 N/C
3 N/C
4 N/C
5 N/C
6 TRIM M1
7 +V OUT M1
8 +V OUT M1
9 -V OUT M1
Outputs M1
10
+V OUT M3
11 +V OUT M3
12 -V OUT M3
13 + SENSE M2
14 TRIM M3
15 - SENSE M2
16 +V OUT M2
17 -V OUT M2
18 -V OUT M2
PIN DESCRIPTION
1
+V OUT M3
2 -V OUT M3
3 -V OUT M3
4 + SENSE M3
5 - SENSE M3
6 TRIM M2
7 +V OUT M2
8 +V OUT M2
9 -V OUT M2
Outputs M2 and M3
OUTPUT M2 & M3
OUTPUT M1
J2
3
1 +V OUT M2
2 -V OUT M2
3 -V OUT M2
4 +V OUT M2
5 -V OUT M2
6 TRIM M1
7 +V OUT M1
8 +V OUT M1
9 -V OUT M1
Outputs M1 and M2
10 +V OUT M2
11 +V OUT M2
12 -V OUT M2
13 +V OUT M1
14 TRIM M2
15 -V OUT M1
16 +V OUT M1
17 - V OUT M1
18 - V OUT M1
1 +V OUT M4
2 -V OUT M4
3 -V OUT M4
4 +SENSE M4
5
-SENSE M4
6 TRIM M3
7 +V OUT M3
8 +V OUT M3
9 -V OUT M3
Outputs M3 and M4
10
+V OUT M4
11 +V OUT M4
12 -V OUT M4
13 +V OUT M3
14 TRIM M4
15 -V OUT M3
16 +V OUT M3
17 - V OUT M3
18 - V OUT M3
OUTPUTS M1 & M2
OUTPUTS M3 & M4
J2
J3
Note: The type of output connector a FlatPAC-EN has depends on which modules are used. E.g. if a two output configuration uses two half bricks
(instead of a full brick and half brick) this two output configuration will have the 18 pin molex connectors, not stud connectors.
(Note: The Molex connectors are limited to 9A/pin (27A/output)
(Note: The Molex connectors are limited to 9A/pin (27A/output)