User Manual
Consult Applications Engineering when trimming outputs below 5V.
Specifications (Typical at 25°C, nominal line and 75% load, unless otherwise specified)
GENERAL
Number of Outputs 1-4
Modules VI-200/VI-J00, VE-200/VE-J00: Maxi/Mini/Micro
Efficiency Typically > 70%
Safety Agency Approvals cURus – UL 60950-1, CSA 60950-1
cTUVus – EN 60950-1, UL 60950-1, CSA 60950-1
CE Mark – Low Voltage Directive, 73/23/EEC amended by 93/68/EEC
Vibration Mil-STD 810 Minimum Integrity (MI chassis only)
Shock Mil-STD 810 40G Functional Shock (MI chassis only)
Maximum Output Power Up to 500 Watts; 425 Watts for EN 61000-3-2/A14 compliance
(not to exceed input current of 9A) (105/190 Vac minimum input)
INPUT
Input 90-132/180-264 Vac 47-63Hz
250-380 Vdc
Inrush Current 8.5A peak @ 115 Vac and 17A peak at 230 Vac
Line/Load Regulation
VI200/VI-J00:± 0.2% max.10% to full load; ± 0.5% max. No load to 10% load
Line Regulation* Maxi/Mini/Micro:± 0.20% max. to 0.3% max LL to HL, Full Load
Ride Through Time 500W 400W
@ 115Vac (typical) 12ms 15ms
@ 230Vac (typical) 16ms 18ms
Harmonic Distortion EN61000-3-2 A/14 (For output power ≤ 425W or input current not
in excess of 3.33 A rms at 230 Vac, 50 Hz.)
Conducted EMI FCC and EN 55022 Class A
(certain configurations meet EN 55022 Class B)
Mil-STD 461 may require external filter - contact factory
Power Factor >.70
Transient Burst Immunity EN61000-4-4
Surge Immunity EN61000-4-5
Voltage Dips EN61000-4-11
Dielectric Withstand Primary to Chassis GND = 1,500 V
RMS
Primary to Secondary = 3,000 VRMS
Secondary to Chassis GND = 500 VRMS
* See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of normal output voltage.
OUTPUT
VI-200/VI-J00 Modules
Parameter MIN. TYP. MAX. UNITS NOTES
Setpoint Accuracy* 0.5 1 % of Vnom
Load/line Regulation ±0.2 % 10% to Full Load
Load/line Regulation ±0.5 % Load to 10%
Temperature Regulation 0.01 0.02 %/°C Over rated temp.
Long Term Drift 0.02 %/K hours
Output Ripple & Noise:
VI/E-200 100 mV p-p See module design guide
VI/E-J00 100 mV p-p for exact specifications
Voltage Trim Range
VI-200/VI-J00 Slots 50-110 % V out ± 10% on 10-15 Vout
Total Remote Sense Compensation 0.5 Volts Autosense. See pg.14
OVP Set Point
1
115 125 135 %Vout Recycle Power
Current Limit 105 115 125 % of I max Auto Recovery
Short Circuit Current 20 (105
2
) 130 %
Overtemperature Limiting Not available on VI-J00
*
For special and adjustable voltages, maximum setpoint accuracy is 2% of Vnom.
1
131% Nominal for Booster Modules. No OVP for VI-J00
Pg 18 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474 03-000050 rev A
FlatPAC-EN/EN MI Design Guide