+Sense and –Sense must be connected locally or remotely (shown).
+ V
OUT
To Load
– V
OUT
R1
10K
R2
+ OUT
+ SENSE
TRIM
– SENSE
– OUT
RESISTOR VALUES FOR TRIMMING STANDARD OUTPUT VOLTAGES
Nominal Output Voltage 5 V 12 V 15 V 24 V 28 V 48 V Trim Range
R1(kΩ) .953 15.8 22.1 41.2 48.7 90.9
R2(kΩ)909090909090
+10%, -10%
V
LINE
> 90 (180) Vac
AC Line
Interrupted
AC
Line
AC OK
DC OK
T0
T1 T2
T3
T4
Conditions: Full Load 90 (180) Vac, AC Line
Timing Diagram—Status Signals (2-up and 3-up models)
Output Trimming (All models with VI-200s)
Battery
Charger
External
Control
Functions
+ OUT
V
TRIM
I
TRIM
I
MON
– OUT
Programmable
Current Source
12–48V
Battery
+
–
➧
➧
Load
+
–
OR
Typical Applications (FlatPACs with BatMods only)
Time Interval Min Typ Max Units Notes
T1-T0 0 0.1 1.0 ms
T3-T2 0 – – ms
T4-T2 5 – – ms Ride-through time
T4-T3 5 – – ms AC fail warning time