Owner manual

Javelin I & II Power Supply Operator’s Manual
Specifications
(Typical at 25C, nominal line and 75% load, unless otherwise specified)
General
Number of Outputs 1
Efficiency 75%
Safety Approvals N/A
MIL-STD’s 461E; 704E; 810E; 1399
Maximum Output Power 800W, >104 VAC
1200W, >160 VAC
1800W, >212 VAC (Selected Output Voltages)
Input
Input 85-254 VAC, 47-500Hz
85-380 VDC
Line Regulation 0.2% from 10% load to full load
Inrush Current 30A rms. max. @ 115 VAC
60A rms. max. @ 230 VAC
Ride-Through Time 20 ms at 1200W load
Conducted EMI FCC Class A, EN 55022 Class B
MIL-STD-461E
Power Factor .99 (115 VAC 800W load)
.95 (230 VAC 1200W load)
Transient Surge IEC 801-5 level 3
(Common Mode & Normal Mode)
Dielectric Withstand Primary to Chassis GND = 2121 VDC
Primary to Secondary = 4242 VDC
Secondary to Chassis GND = 500 VDC
Output
Parameter MIN. TYP. MAX. UNITS NOTES
Setpoint Accuracy
0.5 1
% of V
NOM
Load/Line Regulation
0.02 0.2
% of V
NOM
0% to 100%
Temperature Regulation
0.002 0.005
%C 20 to 100C
Long Term Drift
0.02
%1K hours
Output Ripple pp:
2V, 3.3V
100
mV 20 MHz bandwidth
5V
2
% 20 MHz bandwidth
12-95V
1
% 20 MHz bandwidth
Trim
90
110 % of V
NOM
Total Remote Sense Compensation
0.5
Volts 0.25V max. each leg
OVP Set Point
112
135 % of V
NOM
Recycle power
Current Limit
102
135 % of I max Automatic restart
Over-Temperature Protection
85>TA<95
Varies according to
power level
Rev. 05/11/2012 Mission Power Solutions (760) 631-6846 sales@mpwrs.com Pg. 12