Owner manual

Javelin I & II Power Supply Operator’s Manual
Environmental
MIL-STD
810E
Storage Temperature
C Grade
40C to 125C
T Grade
40C to 125C
H Grade
55C to 125C
M Grade
65C to +125C
Operating Temperature
C Grade, Full Power
20C to +55C
C Grade, Half Power
20C to +70C
T Grade, Full Power
40C to 55C
T Grade, Half Power
40C to 70C
H Grade, Full Power
40C to 55C
H Grade, Half Power
40C to 70C
M Grade, Full Power
55C to 55C
M Grade, Half Power
55C to 70C
Product Weight
11.50 lbs. (11.0 lbs. Javelin II)
Dimensions 4.9 H (124,46mm) x 7.0 W (177,8mm) x 10.75 L (273,1mm)
[9.5 L (241,3mm) for Javelin II]
Warranty
1 Year Limited
Rev. 05/11/2012 Mission Power Solutions (760) 631-6846 sales@mpwrs.com Pg. 13
INPUT POWER
RATING MAXIMUM INPUT TYPE (#) INPUT VOLTAGE RANGE
(WATTS) Vout >10 / Vout<10
1 600 (1) SINGLE PHASE 80 / 85 TO 254 VAC
(2) DIRECT CURRENT80 / 85 TO 380 VDC
2 800 (1) SINGLE PHASE 102 / 108 TO 254 VAC
(2) DIRECT CURRENT102 / 108 TO 380 VDC
3 1200 (1) SINGLE PHASE 146 / 158 TO 254 VAC
(2) DIRECT CURRENT146 / 158 TO 380 VDC
4 1600 (1) SINGLE PHASE 192 TO 254 VAC
(2) DIRECT CURRENT192 TO 380 VDC
5 1800 (1) SINGLE PHASE 215 TO 254 VAC
(2) DIRECT CURRENT215 TO 380 VDC
Maximum Output Power vs. Input Voltage AC or DC
0
200
400
600
800
1000
1200
1400
1600
1800
2000
50 100 150 200 250
Minimum Input Voltage AC or DC
Maximum Output Pow er
Output Voltages > 10Vdc Output Voltages <10 Vdc
Maximum Output Power vs. Temperature
0
200
400
600
800
1000
1200
1400
1600
1800
2000
0 20 40 60 80 100
TA max
Pout max
400W
600W
800W
1200W
1600W
1800W
Graph 1. Maximum Output Power vs. Input Voltage