SAFETY CONSIDERATIONS
F
using. Safety agency conditions of acceptability require
that the module positive (+) Input terminal be fused and
the baseplate of the converter be connected to earth
ground. The following table lists the acceptable fuse types
a
nd current rating for the Maxi, Mini, Micro Family of
DC-DC converters. Safety Certifications on the Vicor web
site should always be consulted for the latest fusing
requirements.
Acceptable Fuse Types and Current Rating for the Maxi, Mini, Micro Family of Converters
Package Size Input Voltage Output Voltage Output Power Required Fuse
Maxi (A) 375 2 160 Bussmann PC-Tron 5A
Maxi (A) 375 3.3 264 / 200 Bussmann PC-Tron 5A
Maxi (A) 375 5, 8 400 / 300 Bussmann PC-Tron 5A
Maxi (A) 375 12, 15, 24, 28, 32, 36, 48, 54 600 / 400 Bussmann PC-Tron 5A
Mini (B) 375 2 100 Bussmann PC-Tron 5A
Mini (B) 375 3.3 150 / 100 Bussmann PC-Tron 5A
Mini (B) 375 5, 8 200 / 150 Bussmann PC-Tron 5A
Mini (B) 375 12, 15, 24, 28, 36, 48 300 / 200 Bussmann PC-Tron 5A
Micro (C) 375 2 50 Bussmann PC-Tron 3A
Micro (C) 375 3.3 75 / 50 Bussmann PC-Tron 3A
Micro (C) 375 5, 8 100 / 50 Bussmann PC-Tron 3A
Micro (C) 375 12, 15, 24, 28, 36, 48 150 / 75 Bussmann PC-Tron 3A
Maxi (A) 300 2 160 Bussmann PC-Tron 5A
Maxi (A) 300 3.3 264 / 200 Bussmann PC-Tron 5A
Maxi (A) 300 5, 8 400 / 300 Bussmann PC-Tron 5A
Maxi (A) 300 12, 15, 24, 28, 36, 48 500 / 400 Bussmann PC-Tron 5A
Mini (B) 300 2 100 Bussmann PC-Tron 5A
Mini (B) 300 3.3 150 / 100 Bussmann PC-Tron 5A
Mini (B) 300 5, 8 200 / 150 Bussmann PC-Tron 5A
Mini (B) 300 12, 15, 24, 28, 36, 48 250 / 150 Bussmann PC-Tron 5A
Micro (C) 300 2 50 Bussmann PC-Tron 3A
Micro (C) 300 3.3 75 / 50 Bussmann PC-Tron 3A
Micro (C) 300 5, 8 100 / 50 Bussmann PC-Tron 3A
Micro (C) 300 12, 15, 24, 28, 36, 48 150 / 75 Bussmann PC-Tron 3A
Maxi (A) 150 3.3 264 / 200 Bussmann ABC-8
Maxi (A) 150 5, 8 400 / 300 Bussmann ABC-8
Maxi (A) 150 12, 15, 24, 28, 36, 48 500 / 400 Bussmann ABC-8
Mini (B) 150 3.3 150 / 100 Bussmann PC-Tron 5A
Mini (B) 150 5, 8 200 / 150 Bussmann PC-Tron 5A
Mini (B) 150 12, 15, 24, 28, 36, 48 250 / 150 Bussmann PC-Tron 5A
Micro (C) 150 3.3 75 Bussmann PC-Tron 3A
Micro (C) 150 5, 8 100 Bussmann PC-Tron 3A
Micro (C) 150 12, 15, 24, 28, 36, 48 150 Bussmann PC-Tron 3A
Maxi (A) 110 3.3 200 / 150 Bussmann ABC-8
Maxi (A) 110 5, 8 300 / 200 Bussmann ABC-8
Maxi (A) 110 12, 15, 24, 28, 36, 48 400 / 300 Bussmann ABC-8
Mini (B) 110 3.3 100 / 75 Bussmann PC-Tron 5A
Mini (B) 110 5, 8 150 / 100 Bussmann PC-Tron 5A
Mini (B) 110 12, 15, 24, 28, 36, 48 200 / 150 Bussmann PC-Tron 5A
Micro (C) 110 3.3 50 Bussmann PC-Tron 3A
Micro (C) 110 5, 8 75 Bussmann PC-Tron 3A
Micro (C) 110 12, 15, 24, 28, 36, 48 100 Bussmann PC-Tron 3A