11. Filter Input Attenuator Module (FIAM) Family
F
IAM1 FIAM2 M-FIAM3 Notes
Input voltage 36 – 76 Vdc 36 – 76 Vdc 180 – 375 Vdc Continuous
Recommended fusing (F1): Bussman ABC–10 Bussman ABC-20 Bussman ABC-3
Output current: 10 A 20 A 3 A Maximum
External capacitance (C1) 10 µF min – 150 µF max 100 µF min – 330 µF max 10 µF min – 22 µF max
Inrush limiting 0.014 A/µF 0.014 A/µF 0.018 A/µF Maximum
EMI/RFI
Bellcore GR-001089-Core, Bellcore GR-001089-Core, MIL-STD-461E, CE101
EN55022 Class B, FCC EN55022 Class B, FCC CE102, CS101, CS114
Part 15 Class B Part 15 Class B CS115, CS116
Transient immunity
Bellcore TR-NWT-0004999, Bellcore TR-NWT-0004999, Exceeds limits of MIL-STD-
ETS 300 386-1, Class 2 ETS 300 386-1, Class 2 704E/F
Mini package size 2.28" x 2.2" x 0.5" 2.28" x 2.2" x 0.5" 2.28" x 2.2" x 0.5"
Table 11–1 — FIAM Family Specifications (See specific data sheets for more detail)
M-FIAM5B M-FIAM9 Notes
Input voltage 14 – 36 Vdc 10 – 36 Vdc Continuous
Recommended fusing (F1): Bussman ABC-20 Bussman ABC-20
Output current: 20 A 18 A Maximum
External capacitance (C1) 330 µF min –1000 µF max 330 µF min –1000 µF max
Inrush limiting 0.007 A/µF 0.007 A/µF Maximum
EMI/RFI
MIL-STD-461E, CE101 MIL-STD-461E, CE101
CE102, CS101, CS114 CE102, CS101, CS114
CS115, CS116 CS115, CS116
Transient immunity
50 V Max. 12.5 ms per MIL- 100 Vdc 50 ms per MIL-STD-
STD-704E/F, cont. operation 1275A/B/D, 250 Vdc 70 µs
per MIL-STD-1275A/B/D, 70
Vdc 20 ms per MIL-STD-704A.
50 Vdc 12.5 ms per MIL-STD-
704E/F, cont. operation
Mini package size 2.28" x 2.2" x 0.5" 2.28" x 2.2" x 0.5"