Specifications (Cont.)
Environmental
Storage temperature -40°C ~ +85°C
Operating temperature -20°C ~ +55°C (Extended temperature range is available; -40°C to +55°C)
Functional shock
MIL-STD 810F Method 516.5 procedure 1,
terminal peak saw-tooth wave, 40G 11 mS
Vibration MIL-STD 810G for minimum integrity vibration
Humidity 95% non condensing
Cooling Fan cooled (field replaceable) temperature speed control
Electromagnetic Compatibility
EN61000-6-1n European General EMC Immunity
IEC 61000-4-11 [50 Hz] Voltage Dips 30% for 0.5 prd, pc C Voltage Interrupts (pc C)
IEC 61000-4-4 [TRANSIENT]
EFT/Burst ± 1 kV AC leads ± 500 V DC leads.
5/50 nsec 5 kHz rep rate (pc B)
IEC 61000-4-5 [SURGE]
Power line Surge AC in ± 2 kV CM ± 1 kV DM DC in
± 500 V CM & DM 1.2/µSec (pc B)
EN 61000-4-6 [0.15 to 80 MHz]
RF Common Mode Input leads, AC & DC leads,
CDN 150 kHz to 80 MHz, 3 Vrms with 80% AM @1 kHz (pa A
)
EN 61000-4-2 [ELECTROSTATIC] Electrostatic Discharge ± 4 kV Contact ± 8 kV Discharge (pc B)
EN 61000-4-3 RF E-Field 80 MHz to 1 GHz 3 V/m with 80% AM @ 1 kHz (pc A)
EN 61000-4-8 Power Freq H-Field 3A/M @ 50 Hz (pa A)
Reliability
FIT TBD
Service life 5 Years
Safety & Regulatory
UL UL 60950-1:2007 CAN C22.2 No. 60950-1-07
CSA CSA*60950 3rd Edition (CB Report to include all national deviations)
EN EN 60950-1/A1:2010
IEC 60950-1-2005 2 Ed. +A1:2009