Manual

UG:110 vicorpower.com Applications Engineering: 800 927.9474 Page 13
PFC MegaPAC Mechanical Drawing
JUMPER
WITH S1-S2
HERE.
S2S1
230 VAC
AS IS
-OR-
115 VAC
L1/N L2
EARTH
DO NOT
RUN W/O
GROUND
ORIGINAL RE-DESIGNED
OUTPUT PANEL AND STUDS
NOTE: EITHER THE ORIGINAL OR RE-DESIGNED OUTPUT STUD AND PANEL COMBINATION
MAY BE PRESENT. THE NEW OUTPUT PANEL HAS A BRASS INSERT AND THE
STUD IS 1/8 INCH LONGER.
FLANGED
BRASS
NUT
INSERT
MAX SCREW PENETRATION - .15
AND 18-24 AWG STRANDED WIRE.
HOUSING WITH #39-00-0039 TERMINALS
MATING RECEPTACLE IS MOLEX #39-01-2060
ARE MOLEX #39-30-1060 MINI-FIT JR. HDRS.
J1A & J1B REMOTE SENSE/OUTPUT CONNECTORS
6
+RS
-RS
3
DUAL MODUPAC OUTPUT CONNECTIONS
321
USE MOLEX TOLL #11-01-0122.
SENSE
6 -REMOTE
SENSE
(SCALE: NONE)
NOTES: UNLESS OTHERWISE SPECIFIED
6
J1A
+RS
-RS
1
3 +REMOTE
2 & 5 -V OUT
1 & 4 +V OUT
45
+-
+
-
PIN
INPUT LEGEND
21
AIR FLOW
STANDARD
45
- +
- +
J1B
115V OPERATION
JUMPER FOR
J9-1 EARTH GROUND
THRU J9-5) FOR #10 AWG INPUT WIRES
.20 SQ. (5.2 MM) OPENINGS (J9-1
INPUT CONNECTIONS
J9-5 120 VAC
J9-4 120 VAC
J9-3 AC NEUTRAL
J9-2 AC HOT
J9
MAXIMUM TORQUE 10 IN-LBS
CLAMPING SCREWS FOR INPUT LEADS,
.040 X .13 SLOT
WITH TERMINAL #39-00-0039 AND 18-24
MATING RECEPTACLE MOLEX #39-01-2120.
#39-30-1120. CUSTOMER I/O INTERFACE
#11-01-0122.
AWG STRANDED WIRE. USE MOLEX TOOL
J10
MOLEX HEADER MINI-FIT JR. 12 POS
IDENTIFICATION
CONNECTOR
J10 INTERFACE
HDWR:
7
1
12
8
9
2
3
10 11
4
56
Vcc +5V, 0.3A
GEN SHUTDOWN
AC POWER OK
SIGNAL GROUND
J10-12
J10-11
J10-1O
J10-11
J10-1O
J10-12
MegaPAC
WESTCOR
mini
M4/#8-32 THDS 16 PLACES
GEN SHUTDOWN
AC POWER OK
SIGNAL GROUND
J10 (ACOK) INTERFACE PIN OUT
(10-040921-38 ASSEMBLY ONLY)
J10 (STD) INTERFACE PIN OUT
E/D-2J10-2
J10-8
J10-7
J10-6
J10-9
J10-5
J10-4
J10-3
NC
NC
NC
E/D-5
E/D-4
E/D-3
J10-1 E/D-1
J10-6
J10-7
J10-9
J10-8
J10-4
J10-3
J10-5
J10-2
J10-1
E/D-2
Vcc +5V, 0.3A
/AC POWER OK
NC
NC
E/D-4
E/D-3
E/D-5
E/D-1
TOOL #57005-5000.
AND 22-28 AWG STRANDED WIRE. USE MOLEX
#39-01-0043 USING #39-00-0031 TERMINALS
MOLEX #39-27-0042 TO MATE WITH HSG
"POWER GOOD" CONNECTOR WHEN "POWER GOOD"
MODUPAC REMOVAL
MODUPACS, 5 PLACES
TO SECURE/REMOVE
#4-40 CAPTIVE SCREWS
APPROXIMATELY
LABEL LOCATED
AS SHOWN
PARALLEL OUTPUTS
BUS BARS - FOR
OPTION IS SPECIFIED.
HDWR:
J3
(MODULES MUST BE ADJACENT)
SERIES OUTPUTS
BUS BAR - FOR
SIGNAL GROUND
POWER GOOD INV.
POWER GOOD
2
J3
1
Vcc
4
3
PIN
TYP.
-P1
HDWR:
"REMOTE SENSE" & "TRIM PIN ACCESS" CONNECTOR
SERRATED FLANGED NUTS
1/4 - 20 ZINC PLATED STEEL,
AS SHOWN (TYP)
(MODUPAC MODEL NO.)
APPROXIMATELY
LABEL LOCATED
45 IN-LBS ±5
(DUAL MOD)
J1B-PIN1
AIR BLOCK
(NO "POWER GOOD"
TYP.
+P1
(EXAMPLE)
OPTION AVAILABLE)
DUAL MODUPAC
1
R12
WHEN ADJUSTABLE OUTPUT
- REMOTE SENSE
+ REMOTE SENSE
TRIM PIN
J2-PIN1
TYP.
OPTION IS SPECIFIED.
R4 "TRIMPOT" PRESENT
3
J2
+P5
2
PIN
1
J2
J1A-PIN1
(DUAL MOD)
J3-PIN1
(SAME AS J2)
R4
C
L
USE MOLEX TOOL #11-01-0118.
TERMINALS AND 22-24 AWG STRANDED WIRE.
#50-57-9403 HSG, USING #16-02-0103
MOLEX #705-53-0002 TO MATE WITH
(SAME AS J2)
J2B-PIN1
J2A-PIN1
-P5 TYP.
C
L
(238.8 MM)
J9-1
(26.9 MM)
.50 (12.7 MM)
1.06
(5.6 MM)
.220
(74.2 MM)
2.920
FAN
.45 (11.4 MM)
(231.3 MM)
9.10
9.40
(121.8 MM)
4.800
3.38 (85.8 MM)
(89.4 MM)
3.52
(30.2 MM)
(153.4 MM)
6.04
1.19
1.80
J9-5
(129.5 MM)
5.10
.60 (15.2 MM)
8.78 (223.0 MM)
(45.7 MM)
(69.6 MM)
(15.7 MM)
.62
(35.6 MM)
2.74
1.40
.729 (18.52)
(18.5 MM)
2.91 (73.9 MM)
4=SP. @ .7285
1.93 (49.0 MM)
V
COR
I