Instruction Manual
UG:013 vicorpower.com Applications Engineering: 800 927.9474 Page 18
Line and Load connections
n Make sure that input power supply is OFF.
n Connect the input power supply positive lead to the +IN input lug of the
evaluation board.
n Connect the input power supply return lead to the –IN input lug of the
evaluation board.
n Connect the output lug +OUT to the positive terminal of the electronic load.
n Connect the output lug –OUT to the return terminal of the electronic load.
n Verify proper polarity of the connections.
n Place the input capacitance 22 uF, 100 V.
n Turn the FAN ON.
n Have the latest version of the datasheet.
Board Operating Modes
PRM evaluation board supports both Adaptive Loop and Remotes Sense Operation.
Therefore, operating mode selection switch S10 is provided on the board for selection of
the following operating modes:
n Default / Adaptive loop using PRM
n Adaptive loop using PRM and VTM
n Remote Sense: local sensing (single ended)
n Remote Sense: non-isolated remote sense (dierential)
n Slave (for array operation)
ON
SGND
SHARE/CONTROL NODE
TRIM
EAO
IF B
IMON
LOCAL SENSE_ +
PRM_ +OUT
+SENSE_B
-SENSE_B
+SENSE
-SENSE
REF/REF_EN
VAUX
VCC
REF_ EN_B
VT
VTM_TM
i+S
i-S
iPOUT
1
2
3
4
5
6
7
8
9
18
17
16
15
14
13
12
1110
19
20
S10
SW_21910MST
iPOUT
Figure 8.
Mode select switch