Instruction Manual

UG:013 vicorpower.com Applications Engineering: 800 927.9474 Page 19
ADAPTIVE LOOP using PRM and VTM
LOCAL SENSE (Single Ended) using PRM
REMOTE SENSE (Dierential) using PRM and VTM
SLAVE using PRM
123456 789 10
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Postion
number
DEFAULT / ADAPTIVE LOOP using PRM
ON
OFF
Figure 9.
Switch configuration
Common features in all modes of operations
n On / o control to enable and disable the PRM
®
in the presence of input power.
n Using switch S11 or
n Open drain MOSFET using external circuitry or function generator
n Input filtering (inductor and ceramic capacitors)
n Output filtering (inductor and ceramic capacitors)
n Sockets for easy installation of input and output electrolytic capacitor
n Test points for current sensing
n Kelvin test points for measurement of input voltage, output voltage and
all signal pins of the PRM.
n Sockets for each test point for easy installation of through-hole components and
solid wires to facilitate the wiring to external circuitry and test equipment.
Figure 9 provides the illustration for how to configure the switch for each operating mode.
2
3
1
S11
S
G
D
SOT 23_3
Q10
0603
R21
SGND
TP23
TP24
H23
H26
TP65
TP66
ENABLE
ON / OFF CONTROL
Figure 10.
ON / OFF control