Line and Load Connections
n Make sure that input power supply is OFF.
n Connect the input power supply positive lead to the +IN input lug of the
evaluation board.
n Connect the input power supply return lead to the –IN input lug of the
evaluation board.
n Connect the output lug +OUT to the positive terminal of the electronic load.
n Connect the output lug –OUT to the return terminal of the electronic load.
n Verify proper polarity of the connections.
n Place the input capacitance 22 uF, 100 V.
n Turn the FAN ON.
n Have the latest version of the datasheet.
Board Operating Modes
Remote Sense PRM evaluation board supports dierent Remote Sense configurations.
Therefore, operating mode selection switch S10 is provided on the board for selection of
the following operating modes:
n Remote Sense: local sensing (single ended)
n Remote Sense: non-isolated remote sense (dierential)