Considerations for Remote Sense only PRM
This board is designed to accomodate dierent types of PRMs. Therefore, certain
circuitry on the board is not populated and there are additional considerations for using
Remote Sense only PRMs.
The Remote Sense PRM Evaluation Board does not operate in default switch S10 setting
which has all switches in the OFF position. Switch at position 1 must remain in the OFF
position. Putting switch at position 1 in the ON position could short the TM pin which
would cause damage. Switch at position 6 must remain in the OFF position as well.
Please see appropriate section for switch setting and mode of operation.
The silkscreen may not match the pin names for Remote Sense PRM. Following table
maps pin names of the Remote Sense PRM to silkscreen and standard PRM.
Remote Sense PRM PRM Silkscreen on the Board
PR SHARE/CONTROL NODE SH/CN
PC ENABLE EN
TM TRIM TRIM
NC NC TP20
NC NC TP19
NC AL AL
VC VC VC
RE REF/REF_EN RE
SG SGND SG
IF IFB IFB
VS VAUX VAUX
NC VT VT
Contents
All Remote Sense PRM evaluation boards arrive with the following contents.
(The user guide can be downloaded from the www.vicorpower.com)
n 1 x Remote Sense PRM evaluation board
n 1 x VI Chip push pin heat sink
n 2 x VI Chip push pins for heat sink installation
n 2 x VI Chip push pin heat sink grounding clips
n 1 x hardware kit
n 1 x through-hole aluminum-electrolytic input capacitor (C
IN
)
n 1 x through hole resistor for default compensation (R28)
n 1 x through hole capacitor for default compensation (C20)
n 2 x jumpers
Table 2.