Manual

3
1
2
~15mm | 0.59’’
Step’s Material
X
5mm
Remove the oor panels and the 3 PET layers from the oor structure.
Unscrew the oor levelers to half their length (about 15 mm - 0.59 in), with exception of the center one, that should stay fully
retracted.
Level the oor structure using the 5mm Hex Key (X) - adjust the center leveler last and make sure it stays in
contact with the oor.
!
The precise leveling of the oor structure is crucial for the correct assembly and operation of the VicBooth Ultra - use
a bubble level. Make sure the oor structure is in its nal position - once assembled, the VicBooth Ultra should not be
moved.
Bubble Level
up down
!