Specifications

TEMPERATURE REQUIREMENTS FOR
CHARGING BATTERIES
Do not charge batteries at ambient temperatures
less than 50° F/10° C or greater than 10F/
40° C.
TEMPERATURE REQUIREMENTS FOR
OPERATING THE PFT510 TOOL
Do not operate the PFT510 at ambient
temperatures less than 14° F/-1C or greater
than 122° F/50° C.
APPROXIMATE AMOUNT OF PRESSES WITH
A FULLY-CHARGED BATTERY
The following table lists the approximate amount
of presses, according to pipe size, that can be
expected from a fully-charged battery. NOTE:
The amount of presses may vary with pipe
properties, age of the batteries, etc.
Nominal
Diameter
inches
Actual Pipe
Outside
Diameter
inches/mm
Approximate
Amount of Presses
from a Fully-
Charged Battery
½
0.840
136
21.3
¾
1.050
110
26.9
1
1.315
87
33.7
1 ½
1.900
47
48.3
2
2.375
35
60.3
TM-PFT510_7
TM-PFT510OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.
REV_D