Installation, Operation and Troubleshooting Instructions Reach-In Refrigerator and Freezer Cabinets For Models: VR-1, VR-2, VR-3 VF-1, VF-2, VF-3 RS-1D-S7, RS-2D-S7, RS-3D-S7 FS-1D-S7, FS-2D-S7, FS-3D-S7 Manual Part No. 50707403 Rev. 1A Print Date: 09/14/10 11 0 Wo o d c r e s t R o a d , C h e r r y H i l l , N J 0 8 0 0 3 Phone: (856) 428-4200 Fax: (856) 428-7299 Website: www.victory-refrig.com E-Mail: parts@victory-refrig.com order-entry@victory-refrig.com service@victory-refrig.
THANK YOU Thank you for purchasing a Victory Refrigeration Reach-In Refrigerator or Freezer Cabinet! This unit has passed our strict Quality Control Inspection and meets the high standards set by Victory Refrigeration. You have made a quality investment that with proper maintenance will give you years of service. Please read the following installation and maintenance instructions before installing or using your unit. If you have any questions, please call our Customer Service Department at (856) 428-4200.
LIMITED WARRANTY (Continental USA Only) The Seller warrants to the original purchaser, equipment manufactured by Seller to be free from defects in material and workmanship for which it is responsible. The Seller’s obligation under this warranty shall be limited to replacing or repairing at Seller’s option, without charge, F.O.B.
INSTALLATION INSTRUCTIONS Proper installation is the first step to operation. We recommend that your refrigerator or freezer be installed by an authorized Victory Certified Installer. Receiving Shipment All units are performance tested and thoroughly inspected prior to shipment. Upon leaving the factory, all units are in perfect condition. Upon receipt, examine the exterior of the shipment packaging for any signs of rough handling.
equipment such as ovens, ranges, heaters, fryers, steam kettles, etc., and out of direct sunlight. Avoid locating the self-contained refrigerator or freezer in an unheated room, or where the room temperature may be below 55°F. Installing Casters or Legs Refrigerators and freezers are shipped with 1/2” single stud mounted legs or casters. 1.
Electric Supply Wiring should be done by a qualified electrician in accordance with local electrical codes. A separate ground wire must be supplied for all installations. A properly wired refrigerator or freezer will assure proper operation. Electrical supply requirements are on the cabinet serial/data plate. It is recommended that a direct, properly protected line of the proper size wire be installed from the main supply to your refrigerator or freezer.
Installation Checklist After the cabinet has been installed, leveled and cleaned as described, refer to the following checklist prior to start-up. Check for proper electrical hook-up. Check exposed refrigeration line connections for leaks. Make sure refrigeration lines are not dented, kinked or rubbing. Check condenser fan for freedom to rotate without striking any stationary members. Check that cabinet is level.
COMMON REPLACEMENT PARTS Part No.
PERIODIC MAINTENANCE Cabinet Cleaning Victory Refrigeration recommends periodic internal and exterior cleaning as outlined below. Daily Exterior Cleaning 1. 2. 3. Clean surface with a sponge and cleaning solution. Use a non-abrasive cleaner that does not contain chlorine. Polish with a soft cloth, wiping with the grain of the metal. Once a week wipe with a film cutting agent to maintain shine. Weekly Interior Cleaning 1. 2. 3. 4. 5. 6. 7. 8. Remove all food, food related items and shelves.
Keep Clean WARNING: Failure to keep condenser clean may cause premature failure of motor- compressor which will NOT be covered by warranty. Lubrication Unless otherwise specified, all Victory refrigerators and freezers are equipped with permanently lubricated motors. The compressor-motor is a sealed unit and is constantly lubricated when in operation. The condenser and the evaporator motors are equipped with lifetime lubricated bearings which never need to be oiled.
BEFORE CALLING SERVICE GUIDE FOR COMMON PROBLEMS Caution: Disconnect Power Supply Prior To Attempting Any Service! PROBLEM Cabinet not running Condensing Unit on Refrigerator or Freezer runs for prolonged period or continuously Refrigerator or Freezer cabinet temperature too high Cabinet is Noisy Refrigerator is freezing product Refrigerator or Freezer Compressor will not start - hums and trips on overload protector Door won't close tight Digital Thermometer displaying alarm code POSSIBLE CAUSE REMED
NOTES xi
1, 2 & 3 SECTION REFRIGERATOR xii
1 SECTION FREEZER
2 SECTION FREEZER xiv
3 SECTION FREEZER xv
11 0 Wo o d c r e s t R o a d , C h e r r y H i l l , N J 0 8 0 0 3 Phone: (856) 428-4200 Fax: (856) 428-7299 Website: www.victory-refrig.com E-Mail: parts@victory-refrig.com order-entry@victory-refrig.com service@victory-refrig.