Operating instructions
32″W LCD TV   WDE SK-32H635S 
29 
until the Ca210 show x =276, y =278. 
7. Adjust item 7 to check color temperature is saturation or not: Add by 7 steps and then to adjust the item 4 and item 
6 to check the color temperature is saturation or not, until is saturation. 
8. Enter the item 10 to select another color temperature to adjust. 
B. Adjust Normal color-temperature: 
1. Set the pattern generator to pattern 104 or 0 IRE pattern. and adjust the Item 8 Cool color-temperature’s item 8 
value. 
2. Switch the Ca210 to T△uvLv-mode (with press “MODE” button) 
3. Switch the Ca210 channel to Channel 03 (with up or down “MEMORY CH” button) 
4. The LCD-indicator on Ca210 will show T=9300. 
5. Adjust the 9 item: Colortemp_All_Mode_Normal, until Ca210 indicator reached the value T=9300 
6. Adjust item 7 to check color temperature is saturation or not: Add by 7 steps and then to adjust the item 4 and item 
6 to check the color temperature is saturation or not, until is saturation. 
7. Loop the Item 5 and Item 6, until the T=9300 and RG/BG is saturation 
8. Enter the 8 item to select another color temperature to adjust. 
C. Adjust Warm color-temperature: 
1. Set the pattern generator to pattern 104 or 0 IRE pattern. And adjust the Item 8 Cool color-temperature’s item 8 
value. 
2. Switch the Ca210 to T△uvLv-mode (with press “MODE” button) 
3. Switch the Ca210 channel to Channel 03 (with up or down “MEMORY CH” button) 
4. The LCD-indicator on Ca210 will show T=6500. 
5. Adjust the 9 item: Colortemp_All_Mode_warm, until Ca210 indicator reached the value T=6500 
6. Adjust item 7 to check color temperature is saturation or not: Add by 7 steps and then to adjust the item 4 and item 
6 to check the color temperature is saturation or not, until is saturation. 
7. Loop the Item 5 and Item 6, until the T=6500 and RG/BG is saturation 
8. Enter the 8 item to select another color temperature to adjust. 
Press “Exit” button on remote control to quit from factory mode. 